Abstract
OCT has been demonstrated as an efficient imaging modality in various biomedical and clinical applications. However, there is a missing link with respect to the source of contrast between OCT and other modern imaging modalities, no quantitative comparison has been demonstrated between them, yet. We evaluated, to our knowledge, for the first time in vivo OCT measurement of rat brain with our previously proposed forward imaging method by both qualitatively and quantitatively correlating OCT with the corresponding T1-weighted and T2-weighted magnetic resonance images, fiber density map (FDM), and two types of histology staining (cresyl violet and acetylcholinesterase AchE), respectively. Brain anatomical structures were identified and compared across OCT, MRI and histology imaging modalities. Noticeable resemblances corresponding to certain anatomical structures were found between OCT and other image profiles. Correlation was quantitatively assessed by estimating correlation coefficient (R) and mutual information (MI). Results show that the 1-D OCT measurements in regards to the intensity profile and estimated attenuation factor, do not have profound linear correlation with the other image modalities suggested from correlation coefficient estimation. However, findings in mutual information analysis demonstrate that there are markedly high MI values in OCT-MRI signals.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (DFG) (EXC 1086)
This publication has 39 references indexed in Scilit:
- Ultrahigh speed endoscopic optical coherence tomography using micromotor imaging catheter and VCSEL technologyBiomedical Optics Express, 2013
- Mapping remodeling of thalamocortical projections in the living reeler mouse brain by diffusion tractographyProceedings of the National Academy of Sciences, 2013
- Spectral domain optical coherence tomography of multi-MHz A-scan rates at 1310 nm range and real-time 4D-display up to 41 volumes/secondBiomedical Optics Express, 2012
- Three-dimensional Optical Coherence Tomography for Optical Biopsy of Lymph Nodes and Assessment of Metastatic DiseaseAnnals of Surgical Oncology, 2012
- Parametric imaging of the local attenuation coefficient in human axillary lymph nodes assessed using optical coherence tomographyBiomedical Optics Express, 2012
- Weighted dynamic time warping for time series classificationPattern Recognition, 2011
- In vivo diffusion tensor magnetic resonance imaging and fiber tracking of the mouse brainNMR in Biomedicine, 2010
- Implementation and Application of PSF‐Based EPI Distortion Correction to High Field Animal ImagingInternational Journal of Biomedical Imaging, 2009
- Exact indexing of dynamic time warpingKnowledge and Information Systems, 2005
- Accurate measurement of total attenuation coefficient of thin tissue with optical coherence tomographyIEEE Journal of Selected Topics in Quantum Electronics, 2003