Pulse Wave Transit Time Measurements of Cardiac Output in Patients Undergoing Partial Hepatectomy
Authors:
- Yoshiyuki ArakiYAYoshiyuki Araki
- Kenichi MasuiKMKenichi Masui
- Tomiei KazamaTKTomiei Kazama
- Yoshihiro SugoYSYoshihiro Sugo
- Thomas L. ArcherTAThomas L. Archer
- Gerard R. ManeckeGMGerard R. Manecke
- 1 December 2013
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 117 (6) , 1307-1312
Abstract
Measuring cardiac output accurately during anesthesia is thought to be helpful for safely controlling hemodynamics. Several minimally invasive methods to measure cardiac output have been developed as alternatives to thermodilution with pulmonary artery catheterization. We evaluated the reliability of a novel pulse wave transit time method of cardiac output assessment to trend with thermodilution cardiac output in patients undergoing partial hepatectomy. Thirty-one patients (ASA physical status II or III) undergoing partial hepatectomy under general anesthesia were evaluated. Cardiac output measurements by pulse wave transit time method and by thermodilution were recorded after induction of anesthesia, after a change in body positioning to 20° head up, after a change to 20° head down, after volume challenge with 10 mL·kg hydroxyethyl starch 6%, during the Pringle maneuver, and immediately after Pringle maneuver release. Trending was assessed using Bland-Altman analysis and concordance analysis. The direction of change between consecutive pulse wave transit time measurements and the corresponding thermodilution measurements showed a concordance rate of 96.0% (lower 95% confidence interval = 64%), with limits of agreement -1.51 and 1.61 L·min. The pulse wave transit time method had good concordance but fairly wide limits of agreement with regard to trending in patients with changes in preload and systemic vascular resistance. There are potential inaccuracies when vasopressors are used to treat hypotension associated with decreased systemic vascular resistance. The study limitations are that the cardiac output data were collected in a nonblinded fashion, and an existing intraarterial catheter was used, although the system requires only routine, noninvasive cardiovascular monitors. This is a promising technique that currently has limitations and will require further improvements and clinical assessment.Keywords
This publication has 17 references indexed in Scilit:
- Agreement Between Methods of Measurement with Multiple Observations Per IndividualJournal of Biopharmaceutical Statistics, 2007
- Comparison of electrical velocimetry and transpulmonary thermodilution for measuring cardiac output in pigletsPediatric Anesthesia, 2007
- A New Non-Invasive Continuous Cardiac Output Trend Solely Utilizing Routine Cardiovascular MonitorsJournal of Clinical Monitoring and Computing, 2004
- Management of catheter-induced pulmonary artery perforation: a rare complication in cardiovascular operationsThe Annals of Thoracic Surgery, 2001
- A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients †British Journal of Anaesthesia, 2001
- The Relationship Between Modified Pulse Wave Transit Time and Cardiovascular Changes in Isoflurane Anesthetized DogsJournal of Clinical Monitoring and Computing, 1999
- A Meta-Analysis of Studies Using Bias and Precision Statistics to Compare Cardiac Output Measurement TechniquesJournal of Clinical Monitoring and Computing, 1999
- Intraoperative Determination of Cardiac Output Using Multiplane Transesophageal EchocardiographyAnesthesiology, 1998
- Routine Pulmonary Artery Catheterization Does Not Reduce Morbidity and Mortality of Elective Vascular SurgeryAnnals of Surgery, 1997
- PHARMACOKINETIC MODEL DRIVEN INFUSION OF PROPOFOL IN CHILDRENBritish Journal of Anaesthesia, 1991