A high throughput capillary electrophoresis method to obtain pharmacokinetics and quality attributes of a therapeutic molecule in circulation
Open Access
- 1 July 2012
- journal article
- Published by Taylor & Francis in mAbs
- Vol. 4 (4) , 521-531
Abstract
Therapeutic proteins circulating in blood are in a highly crowded, redox environment at high temperatures of ~37°C. These molecules circulate in the presence of enzymes and other serum proteins making it difficult to predict from in vitro studies the stability, aggregation or pharmacokinetics of a therapeutic protein in vivo. Here, we describe use of a high throughput capillary electrophoresis based microfluidic device (LabChip GXII) to obtain pharmacokinetics (PK) of a fluorescently labeled human mAb directly from serum. The non-labeled and labeled mAbs were evaluated in single dose rat PK studies using a traditional ELISA method or LabChip GXII, respectively. The fluorescent dye did not significantly alter clearance of this particular mAb, and PK parameters were comparable for labeled and unlabeled molecules. Further, from the CE profile we concluded that the mAb was resistant to fragmentation or aggregation during circulation. In a follow-up experiment, dimers were generated from the mAb using photo-induced cross-linking of unmodified proteins (PICUP) and labeled with the same fluorophore. The extent of dimerization was incomplete and some monomer and higher molecular weight species were found in the preparation. In rat PK studies, the serum concentration-time profile of the three entities present in the dimer preparation could be followed simultaneously with the GXII technology. While further studies are warranted, we believe this method could be adapted to obtain PK of different forms of antibodies (oxidized, deamidated or various glycosylated species) and other proteins.Keywords
This publication has 17 references indexed in Scilit:
- Assessing Antibody Pharmacokinetics in Mice with In Vivo ImagingThe Journal of Pharmacology and Experimental Therapeutics, 2011
- Antibody-based therapeutics to watch in 2011mAbs, 2011
- Stability of IgG isotypes in serummAbs, 2010
- Micro total analysis systems in biopharmaceutical process developmentBioanalysis, 2009
- A high throughput dimer screening assay for monoclonal antibodies using chemical cross-linking and microchip electrophoresisJournal of Chromatography B, 2009
- Recent Advances in Microfluidic Detection SystemsBioanalysis, 2009
- Microchip assays for screening monoclonal antibody product qualityElectrophoresis, 2008
- Micro Total Analysis Systems: Latest AchievementsAnalytical Chemistry, 2008
- Capillary Electrophoresis in BioanalysisAnalytical Chemistry, 2008
- Stoichiometry of the Interaction between the Major Histocompatibility Complex-Related Fc Receptor and Its Fc LigandBiochemistry, 1999