Self-Calibrated In-Process Photogrammetry for Large Raw Part Measurement and Alignment before Machining
Open Access
Abstract
Photogrammetry methods are being used more and more as a 3D technique for large scale metrology applications in industry. Optical targets are placed on an object and images are taken around it, where measuring traceability is provided by precise off-process pre-calibrated digital cameras and scale bars. According to the 2D target image coordinates, target 3D coordinates and camera views are jointly computed. One of the applications of photogrammetry is the measurement of raw part surfaces prior to its machining. For this application, post-process bundle adjustment has usually been adopted for computing the 3D scene. With that approach, a high computation time is observed, leading in practice to time consuming and user dependent iterative review and re-processing procedures until an adequate set of images is taken, limiting its potential for fast, easy-to-use, and precise measurements. In this paper, a new efficient procedure is presented for solving the bundle adjustment problem in portable photogrammetry. In-process bundle computing capability is demonstrated on a consumer grade desktop PC, enabling quasi real time 2D image and 3D scene computing. Additionally, a method for the self-calibration of camera and lens distortion has been integrated into the in-process approach due to its potential for highest precision when using low cost non-specialized digital cameras. Measurement traceability is set only by scale bars available in the measuring scene, avoiding the uncertainty contribution of off-process camera calibration procedures or the use of special purpose calibration artifacts. The developed self-calibrated in-process photogrammetry has been evaluated both in a pilot case scenario and in industrial scenarios for raw part measurement, showing a total in-process computing time typically below 1 s per image up to a maximum of 2 s during the last stages of the computed industrial scenes, along with a relative precision of 1/10,000 (e.g. 0.1 mm error in 1 m) with an error RMS below 0.2 pixels at image plane, ranging at the same performance reported for portable photogrammetry with precise off-process pre-calibrated cameras.Keywords
This publication has 36 references indexed in Scilit:
- Portable visual metrology without traditional self-calibration measurement modelMeasurement, 2016
- Advances in Large-Scale Metrology – Review and future trendsCIRP Annals, 2016
- Large-scale dimensional metrology (LSDM): from tapes and theodolites to multi-sensor systemsInternational Journal of Precision Engineering and Manufacturing, 2014
- Machine tools for large partsCIRP Annals, 2013
- Raw part characterisation and automated alignment by means of a photogrammetric approachCIRP Annals, 2012
- Recent developments in large-scale dimensional metrologyProceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture, 2009
- Optical measurement techniques for mobile and large-scale dimensional metrologyOptics and Lasers in Engineering, 2009
- Image‐based 3D Modelling: A ReviewThe Photogrammetric Record, 2006
- Advances in photogrammetric measurement solutionsComputers in Industry, 2005
- Large-Scale Metrology – An UpdateCIRP Annals, 2002