Changes in intracuff pressure of a cuffed endotracheal tube during surgery for congenital heart disease using cardiopulmonary bypass
Authors:
- 4 March 2015
- journal article
- research article
- Published by Wiley in Pediatric Anesthesia
- Vol. 25 (7) , 705-710
Abstract
Summary: Background: With the development of newer polyurethane cuffed endotracheal tubes (cETTs), there has been a shift in clinical practice among pediatric anesthesiologists. Despite improvements in design, excessive inflation of the cuff can still compromise tracheal mucosal perfusion. Several perioperative factors can affect the intracuff pressure (CP), and there is no consensus on safe CP in pediatric patients undergoing repair of congenital cardiac disease (CHD) utilizing cardiopulmonary bypass (CPB). In the current study, the CP was continuously monitored in pediatric patients undergoing surgery for CHD.Methods: After IRB approval, this observational study was conducted on pediatric patients who underwent repair of CHD using CPB with a cETT in place. After anesthetic induction and endotracheal intubation, the cuff was inflated using the air leak technique while maintaining a continuous positive airway pressure of 20 cmH2O. After inflation, the CP was continuously monitored throughout the procedure. In addition, temperature and mean arterial pressure (MAP) were also recorded.Results: The study included 33 patients who ranged in age from 1 month to 15.3 years. Their weight ranged from 4.0 to 83.6 kg. Six patients were excluded from the analysis due to the need to add or remove air from the cuff, leaving 27 patients for data analysis for cuff pressure over time. The baseline CP at the time of inflation was 16.1 ± 7.6 cmH2O. With the use of CPB and initiation of hypothermia, when compared to the baseline, the CP decreased by −0.7 ± 5.8 cmH2O at 35–37°C, −9.1 ± 8.4 cmH2O at 31–33°C, −7.8 ± 6.2 cmH2O at 27–29°C, and −11.1 ± 6.0 cmH2O at 2O).Conclusion: There was a significant decrease in the CP during CPB and associated hypothermia. This may offer some protection for mucosal perfusion during CPB which is usually associated with lower than normal MAP. However, the decrease in the CP may compromise the tracheal seal which may not offer the intended protection for the airway from aspiration.Keywords
This publication has 21 references indexed in Scilit:
- Pediatric airway anatomy may not be what we thought: implications for clinical practice and the use of cuffed endotracheal tubesPediatric Anesthesia, 2014
- Cuffed versus Uncuffed Endotracheal Tubes in Pediatric AnesthesiaAnesthesiology, 2013
- Inspiratory Stridor after Tracheal Intubation with a MicroCuff® Tracheal Tube in Three Young InfantsAnesthesiology, 2013
- Effect of cuffed and uncuffed endotracheal tubes on the oropharyngeal oxygen and volatile anesthetic agent concentration in childrenInternational Journal of Pediatric Otorhinolaryngology, 2012
- Cuffed endotracheal tubes in infants and children: Should we routinely measure the cuff pressure?International Journal of Pediatric Otorhinolaryngology, 2011
- Cuffed endotracheal tubes in children reduce sevoflurane and medical gas consumption and related costsActa Anaesthesiologica Scandinavica, 2010
- Cuffed or uncuffed tracheal tubes during anaesthesia in infants and small children: time to put the eternal discussion to rest?British Journal of Anaesthesia, 2009
- Prospective randomized controlled multi-centre trial of cuffed or uncuffed endotracheal tubes in small childrenBritish Journal of Anaesthesia, 2009
- Cuffed tracheal tubes in children: past, present and futureExpert Review of Medical Devices, 2007
- Comparison of Cuffed and Uncuffed Endotracheal Tubes in Young Children during General AnesthesiaAnesthesiology, 1997