Simultaneous high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS-MS) analysis of cyanide and thiocyanate from swine plasma
Authors:
- 12 December 2013
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 406 (3) , 727-734
Abstract
An analytical procedure for the simultaneous determination of cyanide and thiocyanate in swine plasma was developed and validated. Cyanide and thiocyanate were simultaneously analyzed by high-performance liquid chromatography tandem mass spectrometry in negative ionization mode after rapid and simple sample preparation. Isotopically labeled internal standards, Na13C15N and NaS13C15N, were mixed with swine plasma (spiked and nonspiked), proteins were precipitated with acetone, the samples were centrifuged, and the supernatant was removed and dried. The dried samples were reconstituted in 10 mM ammonium formate. Cyanide was reacted with naphthalene-2,3-dicarboxaldehyde and taurine to form N-substituted 1-cyano[f]benzoisoindole, while thiocyanate was chemically modified with monobromobimane to form an SCN-bimane product. The method produced dynamic ranges of 0.1–50 and 0.2–50 μM for cyanide and thiocyanate, respectively, with limits of detection of 10 nM for cyanide and 50 nM for thiocyanate. For quality control standards, the precision, as measured by percent relative standard deviation, was below 8 %, and the accuracy was within ±10 % of the nominal concentration. Following validation, the analytical procedure successfully detected cyanide and thiocyanate simultaneously from the plasma of cyanide-exposed swine.Keywords
This publication has 34 references indexed in Scilit:
- The Analysis of Protein-Bound Thiocyanate in Plasma of Smokers and Non-Smokers as a Marker of Cyanide ExposureJournal of Analytical Toxicology, 2012
- Determination of cyanide exposure by gas chromatography–mass spectrometry analysis of cyanide-exposed plasma proteinsAnalytica Chimica Acta, 2010
- The Analysis of Cyanide and its Breakdown Products in Biological SamplesCritical Reviews in Analytical Chemistry, 2010
- Dual-wavelength β-correction spectrophotometric determination of trace concentrations of cyanide ions based on the nucleophilic addition of cyanide to imine group of the new reagent 4-hydroxy-3-(2-oxoindolin-3-ylideneamino)-2-thioxo-2H-1,3-thiazin-6(3H)-oneAnalytica Chimica Acta, 2010
- LC‐MS Instrument Calibration2004
- Determination of Physiological Levels of Blood Cyanide without Interference by Thiocyanate.Eisei kagaku, 1996
- Spectrofluorimetric determination of cyanide in blodd and urine with naphthalene-2,3-dialdehyde and taurineAnalytica Chimica Acta, 1989
- Spectrophotometric determination of hydrogen cyanide in air and biological fluidsThe Analyst, 1987
- Simultaneous determination of cyanide and thiocyanate by high performance liquid chromatography.Chemical and Pharmaceutical Bulletin, 1982
- Über eine neue, vom Pyridin derivierende Klasse von FarbstoffenJournal für Praktische Chemie, 1904