Surgical flow disturbances in dedicated minimally invasive surgery suites: an observational study to assess its supposed superiority over conventional suites
Open Access
- 20 May 2016
- journal article
- research article
- Published by Springer Nature in Surgical Endoscopy
- Vol. 31 (1) , 288-298
Abstract
Background Minimally invasive surgery (MIS) is frequently compromised by surgical flow disturbances due to technology- and equipment-related failures. Compared with MIS in a conventional cart-based OR, performing MIS in a dedicated integrated operating room (OR) is supposed to be beneficial to patient safety. The aim of this study was to compare a conventional OR with an integrated OR with regard to the incidence and effect of equipment-related surgical flow disturbances during an advanced laparoscopic gynecological procedure [laparoscopic hysterectomy (LH)]. Methods Using video recording, 40 LHs performed between November 2010 and April 2012 (20 in a conventional cart-based OR and 20 in an integrated OR) were analyzed by two different observers. Outcome measures were the number, duration and effect (on a seven-point ordinal scale) of the surgical flow disturbances (e.g., malfunctioning, intraoperative repositioning, setup device). Results A total of 103 h and 45 min was observed. The interobserver agreement was high (kappa .85, p < .001). Procedure time was not significantly different (NS) [conventional OR vs. integrated OR, minutes ± standard deviation (SD), mean 161 ± 27 vs. 150 ± 34]. A total of 1651 surgical flow disturbances were observed (mean ± SD per procedure 40.8 ± 19.4 vs. 41.8 ± 15.9, NS). The mean number of surgical flow disturbances per procedure with regard to equipment was 6.3 ± 3.7 versus 8.5 ± 4.0, NS. No clinically relevant differences in the mean effect of these disturbances on the surgical flow between the two OR setups were observed. Conclusions Performing LH in an integrated OR did not reduce the number of surgical flow disturbances nor the effect of these disturbances. Furthermore, in the integrated OR, repositioning of the monitors was a frequent and time-consuming source of disturbance. In order to maintain the high standard of surgical safety, the entire surgical team has to be aware that by performing surgery in an integrated OR different potential source for disruption arise.Keywords
This publication has 41 references indexed in Scilit:
- Risk factors in patient safety: minimally invasive surgery versus conventional surgerySurgical Endoscopy, 2011
- How do medical device manufacturers’ websites frame the value of health innovation? An empirical ethics analysis of five Canadian innovationsMedicine, Health Care and Philosophy, 2011
- The effect of distractions in the operating room during endourological proceduresSurgical Endoscopy, 2010
- Risk-sensitive events during laparoscopic cholecystectomy: the influence of the integrated operating room and a preoperative checklist toolSurgical Endoscopy, 2010
- Do absorption and realistic distraction influence performance of component task surgical procedure?Surgical Endoscopy, 2009
- Interoperative efficiency in minimally invasive surgery suitesSurgical Endoscopy, 2009
- Quantifying distraction and interruption in urological surgeryQuality and Safety in Health Care, 2007
- Problems with technical equipment during laparoscopic surgerySurgical Endoscopy, 2007
- A theory-based instrument to evaluate team communication in the operating room: balancing measurement authenticity and reliabilityQuality and Safety in Health Care, 2006
- Dedicated minimally invasive surgery suites increase operating room efficiencySurgical Endoscopy, 2001