Open ISEmeter: An open hardware high-impedance interface for potentiometric detection
- 1 May 2016
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (5) , 055111
Abstract
In this work, a new open hardware interface based on Arduino to read electromotive force (emf) from potentiometric detectors is presented. The interface has been fully designed with the open code philosophy and all documentation will be accessible on web. The paper describes a comprehensive project including the electronic design, the firmware loaded on Arduino, and the Java-coded graphical user interface to load data in a computer (PC or Mac) for processing. The prototype was tested by measuring the calibration curve of a detector. As detection element, an active poly(vinyl chloride)-based membrane was used, doped with cetyltrimethylammonium dodecylsulphate (CTA+-DS−). The experimental measures of emf indicate Nernstian behaviour with the CTA+ content of test solutions, as it was described in the literature, proving the validity of the developed prototype. A comparative analysis of performance was made by using the same chemical detector but changing the measurement instrumentation.Keywords
This publication has 22 references indexed in Scilit:
- Ofloxacin Determination in Urine, Serum and Pharmaceuticals Using an Automatic Flow Potentiometric SystemAnalytical Sciences, 2013
- Kinetic Study of the Cetyltrimethylammonium/DNA InteractionThe Journal of Physical Chemistry B, 2009
- Sequential Injection Lab‐on‐Valve Procedure for the Determination of Amantadine Using Potentiometric MethodsElectroanalysis, 2007
- Detection of Catechol by Potentiometric-Flow Injection Analysis in the Presence of InterferentsJournal of Chemical Education, 2007
- Development of a tubular fluoride potentiometric detector for flow analysis: Evaluation and analytical applicationsAnalytica Chimica Acta, 2007
- Flow injection system for potentiometric determination of alkaline phosphatase inhibitorsAnalytica Chimica Acta, 2006
- FIA-potentiometry in the sub-Nernstian response region for rapid and direct chloride assays in milk and in coconut waterTalanta, 2005
- Application of a New pH-Sensitive Electrode as a Detector in Flow Injection PotentiometryElectroanalysis, 2005
- Lead (II) ion selective electrodes based on diphenylmethyl-N-phenylhydroxamic acid ionophore in cyanocopolymer matrixIEEE Sensors Journal, 2001
- Inexpensive device for measurements with ion-selective and pH electrodesAnalytica Chimica Acta, 1990