Implementation of a two‐specimen requirement for verification of ABO/Rh for blood transfusion
- 1 July 2009
- journal article
- Published by Wiley in Transfusion
- Vol. 49 (7) , 1321-1328
Abstract
BACKGROUND: This study presents our implementation of a two‐specimen requirement with no prior record of ABO/Rh to verify patients' blood type before transfusion.MATERIALS AND METHODS: Blood type verification was introduced, discussed, approved, and implemented over a 12‐month period (May 2007 to May 2008). Potential barriers and impact on benchmark indicators were identified and tracked.RESULTS: Inpatient identification and/or specimen labeling for nursing and laboratory phlebotomists baseline corrected error rates were 1:467 and 1:5555, respectively. This study therefore sought and obtained approval to initiate a new policy of blood type verification before blood transfusion. Compliance in turnaround time (TAT) before and after implementation for completion of STAT type and screen/crossmatch within 60 minutes worsened marginally, from 90% to 80%. The impact on use of O–, uncrossmatched blood was found to be manageable. Seven (of 25 total) recorded electronic complaints were received after implementation. The corrected error rate for nurse phlebotomy draws after implementation was 1:630.CONCLUSION: Despite the lack of an instigating event, verification of blood type before blood transfusion was successfully implemented. An impact on resources and benchmark indicators such as TAT can be anticipated and managed. Further process improvement efforts will be needed to ensure safety (e.g., at time of blood transfusion) for patients receiving blood transfusions. ABO/Rh verification may be necessary even after future implementation of bar coding and/or RFID chips, because human errors continue to occur even with systems improvements.Keywords
This publication has 17 references indexed in Scilit:
- Clinical Outcomes of ABO-Incompatible RBC TransfusionsAmerican Journal of Clinical Pathology, 2008
- Nearly Two Decades Using the Check-Type to Prevent ABO-Incompatible TransfusionsAmerican Journal of Clinical Pathology, 2006
- Getting the right blood to the right patient: the contribution of near-miss event reporting and barrier analysisTransfusion Clinique et Biologique, 2005
- Failure of bedside ABO testing is still the most common cause of incorrect blood transfusion in the Barcode eraTransfusion and Apheresis Science, 2005
- Analysis of ABO discrepancies occurring in 35 French hospitalsTransfusion, 2004
- Current performance of patient sample collection in the UKTransfusion Medicine, 2004
- Transfusion Medicine — Blood TransfusionNew England Journal of Medicine, 1999
- Errors in blood transfusion in Britain: survey of hospital haematology departmentsBMJ, 1994
- A report of 104 transfusion errors in New York StateTransfusion, 1992
- Reports of 355 transfusion‐associated deaths: 1976 through 1985Transfusion, 1990