Clinical validation of the AMTAS automated audiometer
- 3 April 2013
- journal article
- research article
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 52 (5) , 342-349
Abstract
Objective: To validate the air- and bone-conduction AMTAS automated audiometry system. Design: Prospective study. Test-retest reliability was determined by assessing adults with AMTAS air- and bone-conduction audiometry. Accuracy was determined by comparing AMTAS and manual audiometry conducted on adults. AMTAS testing was conducted in a quiet room and manual audiometry in a sound booth. Study sample: Ten participants for test-retest reliability tests and 44 participants to determine accuracy were included. Participants had varying degrees of hearing loss. Results: For test-retest reliability the overall difference in air-conduction hearing thresholds (n = 119) was 0.5 dB. The spread of differences (standard deviation of absolute differences) was 4.9 dB. For bone-conduction thresholds (n = 99) the overall difference was − 0.2 dB, and the spread of differences 4.5 dB. For accuracy the overall difference in air-conduction hearing thresholds (n = 509) between the two techniques was 0.1 dB. The spread of differences was 6.4 dB. For bone-conduction thresholds (n = 295) the overall difference was 0 dB, and the spread of differences 7.7 dB. Conclusions: Variations between air- and bone-conduction audiometry for automated and manual audiometry were within normally accepted limits for audiometry. However, AMTAS thresholds were elevated but not significantly different compared to other contemporary studies that included an automated audiometer.Keywords
This publication has 22 references indexed in Scilit:
- Audiology education and practice from an international perspectiveInternational Journal of Audiology, 2008
- Misdiagnosis of hearing loss due to ear canal collapse: a report of two casesThe Journal of Laryngology & Otology, 1996
- Attenuation Provided by Four Different Audiometric Earphone SystemsEar & Hearing, 1990
- Reproducibility of Hearing Threshold MeasurementsSupplementary Data on Bone-conduction and Speech AudiometryScandinavian Audiology, 1990
- Comparison of the noise attenuation of three audiometric earphones, with additional data on masking near thresholdThe Journal of the Acoustical Society of America, 1989
- Three Studies Comparing Performance of the ER-3A Tubephone with the TDH-50P EarphoneEar & Hearing, 1988
- Repeatability of High-Frequency Bone Conduction ThresholdsEar & Hearing, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Reliability and validity of industrial audiometry: Implications for hearing conservation program design.The Laryngoscope, 1983
- Comparison of the Auditory Threshold as Measured by Individual Pure Tone and by Békésy AudiometryThe Journal of the Acoustical Society of America, 1957