Experiment and Simulation Study on the Amorphous Silicon Photovoltaic Walls
Authors:
Open Access
- 1 January 2014
- journal article
- research article
- Published by Hindawi Limited in International Journal of Photoenergy
- Vol. 2014, 1-14
Abstract
Based on comparative study on two amorphous silicon photovoltaic walls (a-Si PV walls), the temperature distribution and the instant power were tested; and with EnergyPlus software, similar models of the walls were built to simulate annual power generation and air conditioning load. On typical sunshine day, the corresponding position temperature of nonventilated PV wall was generally 0.5~1.5°C higher than that of ventilated one, while the power generation was 0.2%~0.4% lower, which was consistent with the simulation results with a difference of 0.41% in annual energy output. As simulation results, in summer, comparing the PV walls with normal wall, the heat per unit area of these two photovoltaic walls was 5.25 kWh/m2(nonventilated) and 0.67 kWh/m2(ventilated) higher, respectively. But in winter the heat loss of nonventilated one was smaller, while ventilated PV wall was similar to normal wall. To annual energy consumption of heating and cooling, the building with ventilated PV wall and normal wall was also similar but slightly better than nonventilated one. Therefore, it is inferred that, at low latitudes, such as Zhuhai, China, air gap ventilation is suitable, while the length to thickness ratio of the air gap needs to be taken into account.Keywords
Funding Information
- Program-Novel Technology of Comprehensive Utilization of Solar Energy (2012BAA10B02)
This publication has 14 references indexed in Scilit:
- Investigation on the annual thermal performance of a photovoltaic wall mounted on a multi-layer façadeApplied Energy, 2013
- Investigation on the development potential of rooftop PV system in Hong Kong and its environmental benefitsRenewable and Sustainable Energy Reviews, 2013
- An experimental study of the thermal performance of a novel photovoltaic double-skin facade in Hong KongSolar Energy, 2013
- Building-integrated photovoltaics (BIPV) in architectural design in ChinaEnergy and Buildings, 2011
- Experimental and numerical investigation on the performance of amorphous silicon photovoltaics window in East ChinaBuilding and Environment, 2011
- Energy analysis of façade-integrated photovoltaic systems applied to UAE commercial buildingsSolar Energy, 2010
- Analysis of thermal and electrical performance of semi-transparent photovoltaic (PV) moduleEnergy, 2010
- Performance evaluation of a PV ventilated window applying to office building of Hong KongEnergy and Buildings, 2007
- Influence of a building’s integrated-photovoltaics on heating and cooling loadsApplied Energy, 2006
- Thermal performance estimation for ventilated PV facadesSolar Energy, 2004