SHEAR STRENGTH ESTIMATION OF SEISMIC RETROFITTED RC COLUMN BY EXTENDED WING WALLS
Authors:
- 1 January 2011
- journal article
- Published by Architectural Institute of Japan in Journal of Structural and Construction Engineering (Transactions of AIJ)
- Vol. 76 (661) , 619-627
Abstract
The objective of this paper is to estimate shear strength of seismic retrofitted RC column by extended wing walls connected by post-installed anchors. The experimental variables are vertical joint anchor ratio, shear reinforcement ratio in the column and wing walls. An evaluation method for the shear strength of seismic retrofitted RC column by extended wing walls is proposed based on arch-truss method. The calculated shear strength by this method is correlated with the experimental shear strength than the other previous methods. That result also show that the shear strength and initial stiffness of seismic retrofitted RC column by extended wing walls is higher according to increasing vertical joint anchor ratio.Keywords
This publication has 2 references indexed in Scilit:
- EVALUATION OF SEISMIC CAPACITY OF WALL COLUMNS IN HIGH-RISE REINFORCED CONCRETE FRAME STRUCTURESJournal of Structural and Construction Engineering (Transactions of AIJ), 1992
- STUDIES ON ELASTO-PLASTIC BEHAVIOR OF REINFORCED CONCRETE BEAMS WITH SPANDREL WALLS : Part-2・Discussions on stiffness and ultimate flexure strengthTransactions of the Architectural Institute of Japan, 1973