Lightweight End-to-End Deep Learning Solution for Estimating the Respiration Rate from Photoplethysmogram Signal
Authors:
- Moajjem Hossain ChowdhuryMCMoajjem Hossain Chowdhury
- Nazmul Islam ShuzanNSNazmul Islam Shuzan
- Muhammad E. H. ChowdhuryMuhammad E. H. Chowdhury
- Mamun Bin Ibne ReazMRMamun Bin Ibne Reaz
- Sakib MahmudSakib Mahmud
- Nasser Al EmadiNENasser Al Emadi
- Mohamed Arselene AyariMAMohamed Arselene Ayari
- Sawal Hamid Md AliSASawal Hamid Md Ali
- Ahmad Ashrif A. BakarABAhmad Ashrif A. Bakar
- Syed Mahfuzur RahmanSRSyed Mahfuzur Rahman
- Amith KhandakarAKAmith Khandakar
Open Access
- 16 October 2022
- journal article
- research article
- Published by MDPI AG in Bioengineering
- Vol. 9 (10) , 558
Abstract
Respiratory ailments are a very serious health issue and can be life-threatening, especially for patients with COVID. Respiration rate (RR) is a very important vital health indicator for patients. Any abnormality in this metric indicates a deterioration in health. Hence, continuous monitoring of RR can act as an early indicator. Despite that, RR monitoring equipment is generally provided only to intensive care unit (ICU) patients. Recent studies have established the feasibility of using photoplethysmogram (PPG) signals to estimate RR. This paper proposes a deep-learning-based end-to-end solution for estimating RR directly from the PPG signal. The system was evaluated on two popular public datasets: VORTAL and BIDMC. A lightweight model, ConvMixer, outperformed all of the other deep neural networks. The model provided a root mean squared error (RMSE), mean absolute error (MAE), and correlation coefficient (R) of 1.75 breaths per minute (bpm), 1.27 bpm, and 0.92, respectively, for VORTAL, while these metrics were 1.20 bpm, 0.77 bpm, and 0.92, respectively, for BIDMC. The authors also showed how fine-tuning a small subset could increase the performance of the model in the case of an out-of-distribution dataset. In the fine-tuning experiments, the models produced an average R of 0.81. Hence, this lightweight model can be deployed to mobile devices for real-time monitoring of patients.Keywords
Funding Information
- Qatar National Research Fund (NPRP12S-0227-190164, DIP-2020-004, GUP-2021-019)
- Universiti Kebangsaan Malaysia (NPRP12S-0227-190164, DIP-2020-004, GUP-2021-019)
This publication has 48 references indexed in Scilit:
- Data fusion for estimating respiratory rate from a single-lead ECGBiomedical Signal Processing and Control, 2013
- Multiparameter Intelligent Monitoring in Intensive Care II: A public-access intensive care unit database*Critical Care Medicine, 2011
- Emergency Department Triage Scales and Their Components: A Systematic Review of the Scientific EvidenceScandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 2011
- Infrared Measurement of Carbon Dioxide in the Human Breath: “Breathe-Through” Devices from Tyndall to the Present DayAnesthesia & Analgesia, 2008
- A simple screening tool for identification of community-acquired pneumonia in an inner city emergency departmentEmergency Medicine Journal, 2007
- Worthing physiological scoring system: derivation and validation of a physiological early-warning system for medical admissions. An observational, population-based single-centre study † ‡British Journal of Anaesthesia, 2007
- The objective medical emergency team activation criteria: A case–control studyResuscitation, 2007
- The vexatious vital: Neither clinical measurements by nurses nor an electronic monitor provides accurate measurements of respiratory rate in triageAnnals of Emergency Medicine, 2005
- Respiratory rate predicts cardiopulmonary arrest for internal medicine inpatientsJournal of General Internal Medicine, 1993
- Clinical Antecedents to In-Hospital Cardiopulmonary ArrestChest, 1990