Preserved myocardial energetics in acute ischemic left ventricular failure – studies in an experimental pig model
Authors:
Open Access
- 1 July 2002
- journal article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 22 (1) , 135-142
Abstract
Objective: We hypothesised that acute ischemic left ventricular failure is characterised by depressed systolic and diastolic function combined with inefficiency in oxygen to mechanical work energy transfer. Methods: Eight anaesthetised pigs (32±3 kg) were employed in an in vivo open chest model. Intraventricular combined pressure and conductance catheters were used to generate continuous left ventricular pressure–volume relations. Myocardial oxygen consumption (MVO2) was determined from coronary flow and coronary arteriovenous oxygen difference. After baseline measurements, ischemia was induced by repeated left coronary injections of 50 μm polystyrene microspheres until stroke volume was reduced by 30%. Haemodynamic and biochemical measurements were repeated 30, 90 and 150 min after microembolisation. Results: Coronary embolisation induced a significant reduction in stroke work (2749±504–1473±449 mmHg ml, P≪0.05) at 30 min compared to baseline. Post-embolic contractility was reduced measured by the slope of the preload recruitable stroke work index (66.2±12.8–50.0±5.8 mmHg, P≪0.05) and the slope of the curvilinearly fitted end-systolic pressure–volume relation in V0 (7.1±2.2–4.9±2.2 mmHg/ml, P≪0.05). The dP/dtmin decreased (2076±291–1468±266 mmHg/s, P≪0.05), but there was no significant change in diastolic stiffness or Tau. Following the 30 min measurements, there were only small changes in most indices. We found no change in myocardial oxygen consumption for basal metabolic processes or excitation–contraction coupling (unloaded MVO2), and there were no changes in conversion of oxygen to total mechanical work (MVO2–PVA slope). However, decreased mechanical efficiency (SW/MVO2) paralleled an increased ratio of arterial elastance to ventricular elastance. Conclusions: Coronary microembolisation in pigs induce a stable ischemic left ventricular failure characterised by reduced contractility and minimally impaired diastolic function. In this acute ischemic left ventricular failure, the main contributor to all over cardiovascular inefficiency is increased ratio of arterial- to ventricular elastance, a setting that impairs mechanical efficiency. However, efficiency of oxygen to total mechanical work transfer in the myocardium is unaltered. The mechanism behind this finding is elusive and warrants further investigation.Keywords
This publication has 18 references indexed in Scilit:
- Postischemic mechanoenergetic inefficiency is related to contractile dysfunction and not altered metabolismAmerican Journal of Physiology-Heart and Circulatory Physiology, 2001
- Oxygen wastage of stunned myocardium in vivo is due to an increased oxygen cost of contractility and a decreased myofibrillar efficiencyCardiovascular Research, 2001
- Coronary microembolizationJACC, 2000
- Altered LV inotropic reserve and mechanoenergetics early in the development of heart failureAmerican Journal of Physiology-Heart and Circulatory Physiology, 2000
- Coronary Microembolization—Its Role in acute coronary syndromes and interventionsHerz, 1999
- Alterations in left ventricular mechanics, energetics, and contractile reserve in experimental heart failure.Circulation Research, 1992
- Ventricular energeticsPhysiological Reviews, 1990
- From 'Emax' to pressure-volume relations: a broader view.Circulation, 1988
- Continuous measurement of left ventricular volume in animals and humans by conductance catheter.Circulation, 1984
- A reproducible and stable model of acute ischaemic left ventricular failure in dogsClinical Physiology and Functional Imaging, 1982