Statistical analysis of vibration signals for cavitation detection ISIEA 2009
Author:
- 1 October 2009
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 78-82
Abstract
Cavitation in a centrifugal pump causes deterioration of the hydraulic performance, damage to the pump components, high vibration and noise. To prevent cavitation and maintain pump performance, it is necessary to detect and diagnose the cavitation as early and accurately as possible. This paper presents non-destructive method to detect and diagnose cavitation in centrifugal pumps using statistical analysis of vibration signals. The vibration data was measured close to the discharge port and analysed in the time domain. It has been found that the probability density function (PDF) , Root mean square (RMS) and standard deviation (SD) values of structure vibration can be used successfully for detecting cavitation in centrifugal pump.Keywords
This publication has 3 references indexed in Scilit:
- DETECTION OF CAVITATION PHENOMENON IN A CENTRIFUGAL PUMP USING AUDIBLE SOUNDMechanical Systems and Signal Processing, 2003
- Noise as an indicator of cavitation in a centrifugal pumpAcoustical Physics, 2003
- Density Estimation for Statistics and Data Analysis1986