Development of a biosensor protein bullet as a fluorescent method for fast detection of Escherichia coli in drinking water
Open Access
- 5 January 2018
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (1) , e0184277
Abstract
Drinking water can be exposed to different biological contaminants from the source, through the pipelines, until reaching the final consumer or industry. Some of these are pathogenic bacteria and viruses which may cause important gastrointestinal or systemic diseases. The microbiological quality of drinking water relies mainly in monitoring three indicator bacteria of faecal origin, Escherichia coli, Enterococcus faecalis and Clostridium perfringens, which serve as early sentinels of potential health hazards for the population. Here we describe the analysis of three chimeric fluorescent protein bullets as biosensor candidates for fast detection of E. coli in drinking water. Two of the chimeric proteins (based on GFP-hadrurin and GFP-pb5 chimera proteins) failed with respect to specificity and/or sensitivity, but the GFP-colS4 chimera protein was able to carry out specific detection of E. coli in drinking water samples in a procedure encompassing about 8 min for final result and this biosensor protein was able to detect in a linear way between 20 and 103 CFU of this bacterium. Below 20 CFU, the system cannot differentiate presence or absence of the target bacterium. The fluorescence in this biosensor system is provided by the GFP subunit of the chimeric protein, which, in the case of the better performing sensor bullet, GFP-colS4 chimera, is covalently bound to a flexible peptide bridge and to a bacteriocin binding specifically to E. coli cells. Once bound to the target bacteria, the excitation step with 395 nm LED light causes emission of fluorescence from the GFP domain, which is amplified in a photomultiplier tube, and finally this signal is converted into an output voltage which can be associated with a CFU value and these data distributed along mobile phone networks, for example. This method, and the portable fluorimeter which has been developed for it, may contribute to reduce the analysis time for detecting E. coli presence in drinking water.Keywords
Funding Information
- FICYT (IE09-106)
- IDEPA (IDE/2012/000452)
This publication has 52 references indexed in Scilit:
- Water Microbiology. Bacterial Pathogens and WaterInternational Journal of Environmental Research and Public Health, 2010
- FhuA (TonA), the Career of a ProteinJournal of Bacteriology, 2009
- Gold screen-printed-based impedimetric immunobiosensors for direct and sensitive Escherichia coli quantisationBiosensors and Bioelectronics, 2009
- Structure and Function of Colicin S4, a Colicin with a Duplicated Receptor-binding DomainJournal of Biological Chemistry, 2009
- Recovery and Sequence Analysis of Hepatitis A Virus from Springwater Implicated in an Outbreak of Acute Viral HepatitisApplied and Environmental Microbiology, 2008
- Detection of Viable but Nonculturable Escherichia coli O157:H7 Bacteria in Drinking Water and River WaterApplied and Environmental Microbiology, 2008
- Detection of Escherichia coli in Biofilms from Pipe Samples and Coupons in Drinking Water Distribution NetworksApplied and Environmental Microbiology, 2007
- Colicin BiologyMicrobiology and Molecular Biology Reviews, 2007
- Characterization of a High-affinity Complex Between the Bacterial Outer Membrane Protein FhuA and the Phage T5 Protein pb5Journal of Molecular Biology, 2002
- THE GREEN FLUORESCENT PROTEINAnnual Review of Biochemistry, 1998