Lattice considerations for the use of an X-band transverse deflecting structure (TDS) at SINBAD, DESY
Open Access
- 20 July 2017
- conference paper
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 874 (1) , 012078
Abstract
An X-band TDS is a well-known device for the characterization of the longitudinal properties of an electron bunch in a linear accelerator. It is planned that a novel X-band TDS with variable polarization will be installed within the next few years at SINBAD, an upcoming accelerator R&D facility at DESY. There are several measurements that can be performed with the TDS, each with specific optics requirements to reach the highest possible resolution and keep induced energy spread to a tolerable level. Quadrupoles will be installed between the TDS and the screen to help satisfy these conditions. In this paper, the requirements for the bunch length measurements, a novel 3D charge density reconstruction technique and slice energy measurements are discussed and some simulation results for the slice energy measurement using example lattices are presented.Keywords
This publication has 4 references indexed in Scilit:
- Reconstruction of the 3D charge distribution of an electron bunch using a novel variable-polarization transverse deflecting structure (TDS)Journal of Physics: Conference Series, 2017
- Time-resolved electron beam phase space tomography at a soft x-ray free-electron laserPhysical Review Special Topics - Accelerators and Beams, 2009
- A transverse rf deflecting structure for bunch length and phase space diagnostics2002