γ-ray diagnostic for the CIT
Authors:
- 1 August 1988
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 59 (8) , 1721-1722
Abstract
We have examined the feasibility of a fusion γ-ray diagnostic for the Compact Ignition Tokamak (CIT), which is expected to produce 1020 (d, t) fusion reactions per second. Gamma rays at 16.7 MeV are produced by the t(d, γ)He5 fusion reaction. A Monte Carlo coupled neutron–photon transport code is used to model the expected γ-ray spectrum incident upon a Compton spectrometer backed by a Čerenkov detector. The results indicate that a signal of ∼3×104 counts/s and a signal-to-noise ratio of ∼30 can be achieved.Keywords
This publication has 6 references indexed in Scilit:
- Measurement of the branching ratio(d,γ)H(d,n) using thick tritium gas targetsPhysical Review C, 1986
- Observation of the 16.7 MeV D-T Fusion Gamma Using a Gas Cerenkov DetectorIEEE Transactions on Nuclear Science, 1986
- Detector development for γ-ray diagnostics of D-T fusion reactionsReview of Scientific Instruments, 1985
- Fusion gamma diagnosticsReview of Scientific Instruments, 1985
- Measurement of the Ground-State Gamma-Ray Branching Ratio of theReaction at Low EnergiesPhysical Review Letters, 1984
- A Gas Cerenkov Detector For Measuring 16.7 MeV Gamma Rays From The D(T,Y)5He Reaction1983