Improper Use of a Transtibial Prosthesis Silicone Liner Causing Pressure Ulceration
Authors:
- Tania R. BrunoTBTania R. Bruno
- R Lee KirbyRKR Lee Kirby
- 1 April 2009
- journal article
- case report
- Published by Wolters Kluwer Health in American Journal of Physical Medicine & Rehabilitation
- Vol. 88 (4) , 264-266
Abstract
We present the previously unreported hazard of creating pressure ulceration in a susceptible host by the improper use of a silicone prosthetic liner. An 80-yr-old man sustained a recent transtibial amputation for peripheral vascular disease. His comorbidities included vascular cognitive impairment, type 2 diabetes mellitus, coronary artery disease, anemia of chronic disease, postherpetic neuralgia, and pruritus of uncertain origin. When not using his transtibial prosthesis, he found his 1.5-mm thick silicone liner (ICEROSS) more comfortable to wear than his stump shrinker and thermoplastic protector. Moreover, he repeatedly wore his liner rolled partway down his stump to allow him to scratch pruritic skin. A horizontal, linear, stage 2 ulcer developed on the residual limb under the upper edge of the rolled liner. The ulcer required >3 mos to heal. This case illustrates the importance of candidate selection for roll-on liners, proper patient and professional training, and optimal management of patient comorbidities.Keywords
This publication has 6 references indexed in Scilit:
- Skin Problems in an Amputee ClinicAmerican Journal of Physical Medicine & Rehabilitation, 2006
- Literature review of the possible advantages of silicon liner socket use in trans-tibial prosthesesProsthetics and Orthotics International, 2005
- A staged management diabetes foot program versus standard care: a 1-year cost and utilization comparison in a state public hospital system11No commercial party having a direct financial interest in the results of the research supporting this article has or will confer a benefit upon the authors(s) or upon any organization with which the author(s) is/are associated.Archives of Physical Medicine and Rehabilitation, 2003
- Hygiene problems of residual limb and silicone liners in transtibial amputees wearing the total surface bearing socketArchives of Physical Medicine and Rehabilitation, 2001
- The prevalence and risk factors of falling and fear of falling among lower extremity amputeesArchives of Physical Medicine and Rehabilitation, 2001
- Clinical rehabilitation of the amputeeProsthetics and Orthotics International, 1996