Orbital Bony Reconstruction With Presized and Precontoured Porous Polyethylene–Titanium Implants
Open Access
- 22 September 2020
- journal article
- research article
- Published by Wolters Kluwer Health in Ophthalmic Plastic & Reconstructive Surgery
- Vol. 37 (3) , 284-289
Abstract
Purpose: Complex bony orbital defects are reconstructively challenging due to loss of intraoperative anatomical landmarks and adjacent support. Presized and precontoured porous polyethylene–titanium implants (Medpor Titan 3D Orbital Floor Implant) are designed to reestablish normal orbital floor and medial wall anatomy and are modeled after anatomically averaged orbits. This is the first study to report clinical outcomes with this implant. Methods: This retrospective case series reviewed clinical data and outcomes for patients undergoing orbital reconstruction with a presized and precontoured porous polyethylene–titanium orbital implant from January 2016 to June 2018. Results: A total of 34 orbits of 33 patients were identified (mean age: 43 ± 16 years, 70% men). Most bony defects were a result of trauma and included large orbital floor deformities (100%), medial wall defects (74%), disrupted inferomedial struts (68%), and broken posterior ledges (82%). Symptomatic diplopia (73%) and enophthalmos (89%, mean: 3.7 ± 2.1 mm) were common preoperatively. Many cases were revisions (44%). Mean follow up was 7.8 ± 6.7 months. All patients had improved globe positioning, enophthalmos, and hypoglobus. Seven patients had persistent postoperative diplopia: 6 responded to prism therapy and 1 required strabismus surgery. One patient required retrobulbar hematoma drainage and 1 patient required implant explantation due to chronic infection. Conclusions: Commercially available presized and precon toured porous polyethylene–titanium implants are useful for complex orbital bony defects and can achieve functional improve ments in diplopia, enophthalmos, and extraocular motility with a low incidence of postoperative complications or revisional surgery.Keywords
This publication has 23 references indexed in Scilit:
- Contemporary management of orbital blowout fracturesCurrent Opinion in Otolaryngology & Head and Neck Surgery, 2019
- Surgical correction of diplopia in orbital fracture: Influence of material and designAnnals of Maxillofacial Surgery, 2019
- Evidence-Based MedicinePlastic and Reconstructive Surgery, 2014
- Three-Dimensional Pre-Bent Titanium Implant for Concomitant Orbital Floor and Medial Wall Fractures in an East Asian PopulationArchives of Plastic Surgery, 2014
- Evolving Trends in the Management of Orbital Floor FracturesJournal of Craniofacial Surgery, 2014
- Combined Orbital Floor and Medial Wall Fractures Involving the Inferomedial Strut: Repair Technique and Case Series Using Preshaped Porous Polyethylene/Titanium ImplantsCraniomaxillofacial Trauma & Reconstruction, 2013
- Preformed vs Intraoperative Bending of Titanium Mesh for Orbital ReconstructionOtolaryngology–Head and Neck Surgery, 2013
- Combined Use of Titanium Mesh and Resorbable PLLA-PGA Implant in the Treatment of Large Orbital Floor FracturesJournal of Craniofacial Surgery, 2011
- Use of Porous Polyethylene With Embedded Titanium in Orbital Reconstruction: A Review of 106 PatientsOphthalmic Plastic & Reconstructive Surgery, 2007
- Blow-Out Fracture of the OrbitAmerican Journal of Ophthalmology, 1957