The Application of Digital Volume Correlation (DVC) to Evaluate Strain Predictions Generated by Finite Element Models of the Osteoarthritic Humeral Head
Open Access
- 22 June 2020
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 48 (12) , 2859-2869
Abstract
Continuum-level finite element models (FEMs) of the humerus offer the ability to evaluate joint replacement designs preclinically; however, experimental validation of these models is critical to ensure accuracy. The objective of the current study was to quantify experimental full-field strain magnitudes within osteoarthritic (OA) humeral heads by combining mechanical loading with volumetric microCT imaging and digital volume correlation (DVC). The experimental data was used to evaluate the accuracy of corresponding FEMs. Six OA humeral head osteotomies were harvested from patients being treated with total shoulder arthroplasty and mechanical testing was performed within a microCT scanner. MicroCT images (33.5 µm isotropic voxels) were obtained in a pre- and post-loaded state and BoneDVC was used to quantify full-field experimental strains (≈ 1 mm nodal spacing, accuracy = 351 µstrain, precision = 518 µstrain). Continuum-level FEMs with two types of boundary conditions (BCs) were simulated: DVC-driven and force-driven. Accuracy of the FEMs was found to be sensitive to the BC simulated with better agreement found with the use of DVC-driven BCs (slope = 0.83, r2 = 0.80) compared to force-driven BCs (slope = 0.22, r2 = 0.12). This study quantified mechanical strain distributions within OA trabecular bone and demonstrated the importance of BCs to ensure the accuracy of predictions generated by corresponding FEMs.Keywords
Funding Information
- Canadian Institutes of Health Research
- Engineering and Physical Sciences Research Council (EP/K03877X/1)
This publication has 43 references indexed in Scilit:
- About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: A 3D zero-strain studyJournal of Biomechanics, 2014
- Role of chemical and mechanical stimuli in mediating bone fracture healingClinical and Experimental Pharmacology and Physiology, 2012
- Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular boneJournal of Biomechanics, 2007
- Proximal humeral fractures: Regional differences in bone mineral density of the humeral head affect the fixation strength of cancellous screwsJournal of Shoulder and Elbow Surgery, 2006
- Bone–cement interface of the glenoid component: Stress analysis for varying cement thicknessClinical Biomechanics, 2005
- Stress shielding and bone resorption in shoulder arthroplastyJournal of Shoulder and Elbow Surgery, 2003
- Digital volume correlation: Three-dimensional strain mapping using X-ray tomographyExperimental Mechanics, 1999
- A Model of Bone Adaptation Using a Global Optimisation Criterion Based on the Trajectorial Theory of WolffComputer Methods in Biomechanics and Biomedical Engineering, 1999
- Predicting the compressive mechanical behavior of boneJournal of Biomechanics, 1994
- Validation of an automated method of three-dimensional finite element modelling of boneJournal of Biomedical Engineering, 1993