Abstract
Stand-alone cone beam CT and SPECT systems capable of complex sinusoidal acquisition trajectories have previously been developed for dedicated breast imaging and used in early clinical studies. The fully-3D motions of the SPECT system can view into the chest wall and throughout the breast volume. The polar tilting capability of the CT system has shown a marked improvement in sampling into the chest wall, with comparable <;6 mGy total dose delivered to the volume as with a circular orbit, while eliminating cone beam artifacts because of the fully-3D acquisitions. A hybrid SPECT-CT system, with each individual modality capable of independently traversing complex trajectories around a pendant breast, was recently designed and the practical implementation of this design is presented here. The CT system consists of a 40×30 cm2 CsI(Tl) flat panel imager and an x-ray tube with a 16° W-anode angle, placed on opposing ends of the completely suspended gantry. A linear stage mechanism utilizing a pulley and cabling was implemented to tilt the suspended gantry within 0.02° positioning error about the 3D center of rotation; the fully-3D SPECT system with 16×20 cm2 CZT detector is nested inside the suspended CT gantry, oriented perpendicular to the CT source-detector pair. Both sub-systems are positioned on an azimuthal rotation stage enabling spherical trajectories. Initial imaging results demonstrate that additional off-axis projection views of various phantoms, allowed by the ±15° polar tilting of the CT system, facilitate more complete sampling and markedly improved reconstructions. To date, this is the first implementation of a fully-3D positioning hybrid SPECT-CT system that we are aware of, and could have various applications in diagnostic or therapeutic breast imaging.Keywords
This publication has 9 references indexed in Scilit:
- SU‐E‐l‐01: Investigating the Dependence of 2D and 3D Scatter‐To‐Primary Ratios on Breast Density in Clinical Breast CTMedical Physics, 2012
- InitialIn VivoQuantification of Tc-99m Sestamibi Uptake as a Function of Tissue Type in Healthy Breasts Using Dedicated Breast SPECT-CTJournal of Oncology, 2012
- Initial Evaluation of a Newly Developed High Resolution CT Imager for Dedicated Breast CTLecture Notes in Computer Science, 2012
- Evaluation of tilted cone-beam CT orbits in the development of a dedicated hybrid mammotomographPhysics in Medicine & Biology, 2009
- Breast CTAnnual Review of Biomedical Engineering, 2007
- Performance of dedicated emission mammotomography for various breast shapes and sizesPhysics in Medicine & Biology, 2006
- Cone‐beam volume CT breast imaging: Feasibility studyMedical Physics, 2002
- Dedicated Breast CT: Radiation Dose and Image Quality EvaluationRadiology, 2001
- Ordered subset reconstruction for x-ray CTPhysics in Medicine & Biology, 2001