Multidetector CT imaging of mechanical prosthetic heart valves: quantification of artifacts with a pulsatile in-vitro model
Open Access
- 15 May 2011
- journal article
- cardiac
- Published by Springer Nature in European Radiology
- Vol. 21 (10) , 2103-2110
Abstract
Objectives Multidetector computed tomography (MDCT) can detect the cause of prosthetic heart valve (PHV) dysfunction but is hampered by valve-induced artifacts. We quantified artifacts of four PHV using a pulsatile in-vitro model and assessed the relation to leaflet motion and valve design. Methods A Medtronic Hall tilting disc (MH), and Carbomedics (CM), St Jude (SJM), and ON-X bileaflet valves underwent CT in an in-vitro model using retrospective gating with a 64 detector CT system in stationary and pulsatile conditions. Artifacts and radiopaque component volumes were quantified with thresholds based on surrounding structures and valvular components. Results Hypodense artifacts volumes (mm3) were 1,029 ± 147, 535 ± 53, 371 ± 16, and 366 ± 18 for the SJM, MH, CM and ON-X valves (p < 0.001 except for the latter two valves p = 0.43). Hyperdense artifact volumes were 3,546 ± 141, 2,387 ± 103, 2,003 ± 102, and 3,033 ± 31 for the SJM, MH, CM and ON-X valve, respectively (all differences p < 0.001). Leaflet motion affected hypodense (F = 41.5, p < 0.001) and hyperdense artifacts (F = 53.7, p < 0.001). Closed and moving leaflets were associated with the least and the most artifacts respectively (p < 0.001, both artifact types). Conclusion Both valve design and leaflet motion affect PHV-induced artifacts. Best imaging results may be expected for the CM valve during phases in which the leaflets are closed.Keywords
This publication has 14 references indexed in Scilit:
- Multidetector-row computed tomography imaging characteristics of mechanical prosthetic valves.2011
- Prosthetic heart valve assessment with multidetector-row CT: imaging characteristics of 91 valves in 83 patientsEuropean Radiology, 2011
- Evaluation of Anatomic Valve Opening and Leaflet Morphology in Aortic Valve Bioprosthesis by Using Multidetector CT: Comparison with Transthoracic EchocardiographyRadiology, 2010
- Metal Artifact Reduction From Reformatted Projections for Hip Prostheses in Multislice Helical Computed TomographyInvestigative Radiology, 2009
- Comparison of Multidetector-Row Computed Tomography to Echocardiography and Fluoroscopy for Evaluation of Patients With Mechanical Prosthetic Valve ObstructionThe American Journal of Cardiology, 2009
- Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standardEuropean Radiology, 2008
- Usefulness of a multidetector-row computed tomography scanner for detecting pannus formationThe Annals of Thoracic Surgery, 2004
- A New Algorithm for Metal Artifact Reduction in Computed TomographyInvestigative Radiology, 2003
- Reoperation for prosthetic aortic valve obstruction in the era of echocardiography: trends in diagnostic testing and comparison with surgical findingsJACC, 2001
- Incorrect echocardiographic diagnosis in patients with mechanical prosthetic valve dysfunction: correlation with surgical findingsThe American Journal of Medicine, 2000