Clinical predictors of prosthesis-patient mismatch after aortic valve replacement for aortic stenosis
Authors:
- Orlando SantanaOSOrlando Santana
- Pablo A. UrbandtPUPablo A. Urbandt
- Alexandre M. BenjoABAlexandre M. Benjo
- Lior U. ElkayamLELior U. Elkayam
- Francisco O. NascimentoFNFrancisco O. Nascimento
- Gervasio A. LamasGLGervasio A. Lamas
- Joseph LamelasJLJoseph Lamelas
Open Access
Abstract
We sought to ascertain predictors of Patient Prosthesis Mismatch, an independent predictor of mortality, in patients with aortic stenosis using bioprosthetic valves. We analyzed 2,107 sequential surgeries. Patient Prosthesis Mismatch was calculated using the effective orifice area of the prosthesis divided by the patient's body surface area. We defined nonsignificant, moderate, and severe Patient Prosthesis Mismatch as effective orifice area indexes of .0.85 cm(2)/m, 0.85-0.66 cm(2)/m(2), and <0.65 cm(2)/m(2), respectively. A total of 311 bioprosthetic patients were identified. The incidence of nonsignificant, moderate, and severe Patient Prosthesis Mismatch was 41%, 42, and 16%, respectively. Severe Patient Prosthesis Mismatch was significantly more prevalent in females (82%). In severe Patient Prosthesis Mismatch, the perfusion and the crossclamp times were considerably lower when compared with nonsignificant Patient Prosthesis Mismatch and moderate Patient Prosthesis Mismatch. Patients with severe Patient Prosthesis Mismatch had a significantly higher likelihood of spending time in the intensive care unit and a significantly longer length of stay in the hospital. Body surface area was not different in severe Patient Prosthesis Mismatch when compared with nonsignificant Patient Prosthesis Mismatch. In-hospital mortality in patients with nonsignificant, moderate, and severe Patient Prosthesis Mismatch was 2.3%, 6.1%, and 8%, respectively. Minimally invasive surgery was significantly associated with moderate Patient Prosthesis Mismatch in 49% of the patients, but not with severe Patient Prosthesis Mismatch. Severe Patient Prosthesis Mismatch is more common in females, but not in those with minimal available body surface area. Though operative times were shorter in these patients, intensive care unit and hospital lengths of stay were longer. Surgeons and cardiologists should be cognizant of these clinical predictors and complications prior to valve surgery.Keywords
This publication has 19 references indexed in Scilit:
- Recommendations for Evaluation of Prosthetic Valves With Echocardiography and Doppler UltrasoundJournal of the American Society of Echocardiography, 2009
- Prosthetic Heart ValvesCirculation, 2009
- Influence of Concentric Left Ventricular Remodeling on Early Mortality After Aortic Valve ReplacementThe Annals of Thoracic Surgery, 2008
- Choice of Prosthetic Heart Valve in Today’s PracticeCirculation, 2008
- Doppler echocardiography in normally functioning replacement aortic valves: a review of 129 studies.2007
- Malignant Natural History of Asymptomatic Severe Aortic Stenosis: Benefit of Aortic Valve ReplacementThe Annals of Thoracic Surgery, 2006
- Patient prosthesis mismatch affects short- and long-term outcomes after aortic valve replacement☆European Journal of Cardio-Thoracic Surgery, 2006
- Impact of Prosthesis-Patient Mismatch on Long-Term Survival in Patients With Small St Jude Medical Mechanical Prostheses in the Aortic PositionCirculation, 2006
- Prosthesis-patient mismatch: definition, clinical impact, and preventionHeart, 2005
- Spectrum of Calcific Aortic Valve DiseaseCirculation, 2005