Fellow-eye comparison of posterior capsule opacification with AcrySof SN60AT and AF-1 YA-60BB blue-blocking intraocular lenses
Authors:
- David SpaltonDSDavid Spalton
- Georgia ClearyGCGeorgia Cleary
- James BoyceJBJames Boyce
- Mayank A. NanavatyMayank A. Nanavaty
- Sri ThyagarajanSTSri Thyagarajan
- John MarshallJMJohn Marshall
- 1 September 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (9) , 1489-1494
Abstract
To evaluate intraindividual differences in posterior capsule opacification (PCO) and visual performance of AcrySof SN60AT (Alcon Laboratories) and AF-1 YA-60BB (Hoya Corp.) intraocular lenses (IOLs). Ophthalmology Department, St. Thomas' Hospital, London, United Kingdom. In this prospective single-surgeon standardized-surgical-procedure fellow-eye comparison, an AcrySof SN60AT or an AF-1 YA-60BB IOL was randomized to the first eye of 36 patients and fellow-eye surgery was performed within 4 to 6 weeks. Follow-up was at 1, 3, 6, 12, and 24 months. Best distance- corrected logMAR visual acuity was measured at 100% and 9% contrast. Contrast sensitivity was measured using the Functional Acuity Contrast Test (FACT) on the Optec 3500 instrument (Stereo Optical Company, Inc.). Color vision was assessed with the Farnsworth Munsell 100-hue test. After pupil dilation, digital retroillumination photographs were taken and the percentage area of PCO was calculated using POCO software. Posterior capsule opacification was significantly greater in the AF-1 YA-60BB group than in the AcrySof SN60AT group at all time points (P<.0001), with the difference greatest at 24 months. At 24 months, 100% contrast visual acuity was significantly better in the AcrySof SN60AT group than in the AF-1 YA-60BB group (P = .0313); 9% contrast visual acuity was significantly better in the AcrySof SN60AT group from 6 months onward. There was no significant difference between groups in color vision or contrast sensitivity. Electron microscopy showed the AcrySof SN60AT IOL has a much sharper posterior edge profile. The AcrySof SN60AT IOL had better PCO performance and thus visual performance than the AF-1 YA-60BB IOL. This is attributable to the differences in optic edge design.Keywords
This publication has 25 references indexed in Scilit:
- Edge profile of commercially available square-edged intraocular lensesJournal of Cataract & Refractive Surgery, 2008
- Effect of anterior capsule polishing on posterior capsule opacification and neodymium:YAG capsulotomy rates: Three-year randomized trialJournal of Cataract & Refractive Surgery, 2005
- Posterior Capsule Opacification in the Presence of an Intraocular Lens with a Sharp versus Rounded Optic EdgeOphthalmology, 2005
- Long-term effect of optic edge design in an acrylic intraocular lens on posterior capsule opacificationJournal of Cataract & Refractive Surgery, 2005
- Long-term efficacy of adding a sharp posterior optic edge to a three-piece silicone intraocular lens on capsule opacification: Five-year results of a randomized studyAmerican Journal of Ophthalmology, 2005
- Effect of optic material on posterior capsule opacification in intraocular lenses with sharp-edge opticsRandomized clinical trialOphthalmology, 2005
- Posterior capsule opacification in rabbit eyes implanted with hydrophilic acrylic intraocular lenses with enhanced square edgeJournal of Cataract & Refractive Surgery, 2004
- Posterior capsule opacificationJournal of Cataract & Refractive Surgery, 1999
- The effect of capsulorhexis size on posterior capsular opacification: one-year results of a randomized prospective trialAmerican Journal of Ophthalmology, 1999
- Continuous curvilinear capsulorhexis and intraocular lens biocompatibilityJournal of Cataract & Refractive Surgery, 1996