Comparative analysis of the visual and refractive outcomes of an aspheric diffractive intraocular lens with and without toricity
- 1 October 2013
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 39 (10) , 1485-1493
Abstract
To analyze and compare the postoperative visual and refractive outcomes and patients' visual satisfaction after implantation of an aspheric or an aspheric toric multifocal diffractive intraocular lens (IOL) in eyes with equivalent biometric characteristics. Private clinic, Munich, Germany. Comparative case series. Patients having cataract surgery were assigned to 1 of 2 groups: aspheric, which had AT Lisa 809M IOL implantation, and aspheric toric, which had AT Lisa 909M IOL implantation (corneal toricity ≥0.75 diopter [D]). Visual and refractive postoperative outcomes were evaluated, as was the patient's ability to perform daily tasks related to vision and the incidence of photic phenomena. The aspheric group comprised 77 eyes (42 patients) and the aspheric toric group, 26 eyes (17 patients). A significant improvement in corrected distance and near visual acuity was observed postoperatively in both groups, as was a significant reduction in the astigmatic component J0 (P<.01). The aspheric toric group had significantly better uncorrected intermediate visual acuity (P=.01). In both groups, the postoperative astigmatic power vectors and spherical equivalent were within ±0.50 D in 100% of eyes and in more than 88% of eyes, respectively. No statistically significant differences were found in any subjective patient questionnaire item. There was no difference in the incidence of photic phenomena between the groups (P≥0.16). The addition of a toric surface to the aspheric diffractive multifocal platform resulted in a comparable visual performance and ability to perform visual tasks. The author has no financial or proprietary interest in any material or method mentioned.Keywords
This publication has 24 references indexed in Scilit:
- Visual and Optical Performance With Two Different Diffractive Multifocal Intraocular Lenses Compared to a Monofocal LensJournal of Refractive Surgery, 2011
- Optical analysis, reading performance, and quality-of-life evaluation after implantation of a diffractive multifocal intraocular lensJournal of Cataract & Refractive Surgery, 2011
- Visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses with a +3.0 D additionJournal of Cataract & Refractive Surgery, 2009
- Retinal Straylight and Complaint Scores 18 Months After Implantation of the AcrySof Monofocal and ReSTOR Diffractive Intraocular LensesJournal of Refractive Surgery, 2009
- Visual acuity comparison of 2 models of bifocal aspheric intraocular lensesJournal of Cataract & Refractive Surgery, 2009
- Apodized diffractive versus refractive multifocal intraocular lenses: Optical and visual evaluationJournal of Cataract & Refractive Surgery, 2008
- Prospective study of the Acri.LISA bifocal intraocular lensJournal of Cataract & Refractive Surgery, 2007
- Visual Performance of Patients with Bilateral vs Combination Crystalens, ReZoom, and ReSTOR Intraocular Lens ImplantsAmerican Journal of Ophthalmology, 2007
- Prospective visual evaluation of apodized diffractive intraocular lensesJournal of Cataract & Refractive Surgery, 2007
- European Multicenter Study of the AcrySof ReSTOR Apodized Diffractive Intraocular LensOphthalmology, 2006