Resonance Energy Transfer from Lanthanide Chelates to Overlapping and Nonoverlapping Fluorescent Protein Acceptors
Authors:
- 13 May 2009
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 81 (12) , 5033-5038
Abstract
Förster resonance energy transfer (FRET) is a powerful tool in studying biomolecular interactions. Intrinsically fluorescent lanthanide chelates are increasingly used as FRET donors due to their long emission lifetime that enables the use of time resolution. Fluorescent proteins, on the other hand, owe their popularity to the intrinsic luminescent properties, facilitating their use as fusion proteins. In this investigation, two energy transfer pairs, terbium(III) chelate with green fluorescent protein (GFP) and europium(III) chelate with yellow fluorescent protein (YFP), were studied by expressing the fluorescent protein acceptor as a fusion protein together with Rab21 GTPase. GTP-conjugated lanthanide chelates were used as donor conjugates. In contrast to conventional FRET observed with the Tb3+−GFP pair, a phenomenon called nonoverlapping FRET (nFRET) was observed with the Eu3+−YFP pair. In nFRET, the sensitized emission of the acceptor was measured at shorter wavelength than where the emission of the donor was observed. Regardless of the lower signal levels, nFRET resulted in a substantially higher signal-to-background ratio. Conventional FRET from sensitized acceptor yielded a single apparent fluorescence emission lifetime, while with nFRET two lifetimes were observed. The lanthanide chelates together with fluorescent proteins enable a straightforward and sensitive assay technology in nFRET applications.Keywords
This publication has 25 references indexed in Scilit:
- Simultaneous Monitoring of Discrete Binding Events Using Dual-Acceptor Terbium-Based LRETJournal of the American Chemical Society, 2007
- Homogeneous non-competitive bioaffinity assay based on fluorescence resonance energy transferAnalytica Chimica Acta, 2007
- Homogeneous assay based on low quantum yield Sm(III)-donor and anti-Stokes’ shift time-resolved fluorescence resonance energy-transfer measurementAnalytica Chimica Acta, 2005
- Homogeneous Assay Based on Anti-Stokes' Shift Time-Resolved Fluorescence Resonance Energy-Transfer MeasurementAnalytical Chemistry, 2005
- A Homogeneous and Noncompetitive Immunoassay Based on the Enhanced Fluorescence Resonance Energy Transfer by Leucine Zipper InteractionAnalytical Chemistry, 2002
- THE GREEN FLUORESCENT PROTEINAnnual Review of Biochemistry, 1998
- Luminescent lanthanide chelates—a way to more sensitive diagnostic methodsJournal of Alloys and Compounds, 1995
- Time-resolved detection of energy transfer: Theory and application to immunoassaysAnalytical Biochemistry, 1988
- Intermolecular energy transfer in the bioluminescent system of AequoreaBiochemistry, 1974
- Zwischenmolekulare Energiewanderung und FluoreszenzAnnalen der Physik, 1948