Quantitative Assessment of FDG Uptake in Brown Fat Using Standardized Uptake Value and Dual-Time-Point Scanning
Authors:
- Khaled AlkhawaldehKAKhaled Alkhawaldeh
- Abass AlaviAAAbass Alavi
- 1 October 2008
- journal article
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 33 (10) , 663-667
Abstract
Brown fat is a potential source of false-positive findings on FDG PET. The purpose of this study was to show the variability in body distribution of brown fat, the degree of FDG uptake, the changes on dual-time-point scanning, and determine if dual-time-point scanning can help in differentiating brown fat from malignant lesions. Thirty-two patients were included in this retrospective study (14 male, 18 female, age range: 8–72 years). All patients had hypermetabolic brown fat activity on FDG PET imaging confirmed by computed tomography (CT) scanning. All patients underwent 2 sequential FDG PET scanning (dual-time-point imaging). The average percent change in maximum standardized uptake value (SUVmax) for 120 brown fat spots between time point 1 and time point 2 was calculated. Body distribution of hypermetabolic brown fat in the 32 patients included supraclavicular area (n = 7); cervical and supraclavicular (n = 5); cervical, supraclavicular, and axillae (n = 5); cervical area, supraclavicular, axillae, and paravertebral (n = 8); supraclavicular, cervical, axillae, paravertebral, and mediastinum (n = 4); supraclavicular, cervical, axillae, paravertebral, and upper abdomen (n = 2); and supraclavicular, cervical, axillae, paravertebral, mediastinum, and intercostals (n = 1). SUVmax for brown fat spots ranged from 0.8 to 12.4 and mean SUV was 4.6 + 1.6. On dual-time-point imaging, 91 (76%) of the brown fat spots demonstrated an increase in SUVmax that ranged from 12% to 192% and mean value of 42%, whereas 16 (13%) brown fat spots did not show any change and 11 (11%) spots underwent a drop in SUVmax by 4% to 12%. There was an increase in the number of active brown fat spots in 3 patients on the second time images. Brown fat is a potential source of false positives, which has wide variability in distribution and degree of FDG uptake. On dual-time-point scanning, there is a progressive increase in FDG uptake within most of the hypermetabolic brown fat areas that mimic malignant lesions.Keywords
This publication has 11 references indexed in Scilit:
- Impact of dual-time-point 18F-FDG PET imaging and partial volume correction in the assessment of solitary pulmonary nodulesEuropean Journal of Nuclear Medicine and Molecular Imaging, 2007
- Concomitant Paravertebral FDG Uptake Helps Differentiate Supraclavicular and Suprarenal Brown Fat Uptake From Malignant Uptake When CT Coregistration Is Not AvailableClinical Nuclear Medicine, 2006
- Visual and Semiquantitative Analyses for F-18 Fluorodeoxyglucose PET Scanning in Pulmonary Nodules 1 cm to 3 cm in SizeThe Annals of Thoracic Surgery, 2005
- Focal FDG Uptake in Mediastinal Brown Fat Mimicking Malignancy: A Potential Pitfall Resolved on PET/CTAmerican Journal of Roentgenology, 2004
- Sex-dependent Thermogenesis, Differences in Mitochondrial Morphology and Function, and Adrenergic Response in Brown Adipose TissueJournal of Biological Chemistry, 2002
- Brown adipose tissue: a factor to consider in symmetrical tracer uptake in the neck and upper chest regionEuropean Journal of Nuclear Medicine and Molecular Imaging, 2002
- Dual time point fluorine-18 fluorodeoxyglucose positron emission tomography: a potential method to differentiate malignancy from inflammation and normal tissue in the head and neckEuropean Journal of Nuclear Medicine and Molecular Imaging, 1999
- A PET study of 18 FDG uptake in soft tissue massesEuropean Journal of Nuclear Medicine and Molecular Imaging, 1999
- Whole-body positron emission tomography: normal variations, pitfalls, and technical considerations.American Journal of Roentgenology, 1997
- Human Adipose Tissue Composition and AgeThe American Journal of Clinical Nutrition, 1969