Abstract
BACKGROUND: Platelets (PLTs) stored in PLT additive solution (PAS) are associated with fewer allergic reactions than plasma‐stored PLTs. However, earlier studies could not provide conclusive evidence on febrile reactions and did not analyze other transfusion reactions separately due to limited sample size. We therefore compared incidences of all transfusion reactions of PAS‐B‐PLTs, PAS‐C‐PLTs, and plasma‐PLTs.STUDY DESIGN AND METHODS: In this observational study, all transfusion reactions reported to the national hemovigilance office of the Netherlands from 2006 to 2015 were included.RESULTS: During the study period, a total of 2407 transfusion reactions after PLT transfusions were reported. In that period 553,267 pooled buffy coat–derived PLT units were issued, of which 83,884 were stored in PAS‐B, 45,728 in PAS‐C, and 423,655 in plasma. Regarding transfusion‐related circulatory overload, transfusion‐related acute lung injury, and “other reactions” no significant differences were observed between the PLT products. When PAS‐B‐PLT transfusions were compared to plasma‐PLT transfusions, the overall relative risk (RR; 95% confidence interval [CI]) of transfusion reactions was 0.99 (0.88‐1.11); for allergic and febrile nonhemolytic transfusion reactions (FNHTRs) it was 0.66 (0.55‐0.80) and 1.54 (1.27‐1.86), respectively. When PAS‐C‐PLTs were compared to plasma‐PLTs, the RR (95% CI) was 0.56 (0.46‐0.68) for all transfusion reactions, 0.38 (0.28‐0.52) for allergic reactions, and 0.82 (0.59‐1.13) for FNHTRs. When PAS‐C‐PLTs were compared to PAS‐B‐PLTs, for all reactions the RR (95% CI) was 0.56 (0.45‐0.70) for allergic reactions 0.58 (0.40‐0.82), and for FNHTRs 0.53 (0.37‐0.75).CONCLUSIONS: PAS‐C‐PLTs are associated with fewer transfusion reactions compared to plasma‐PLTs and compared to PAS‐B‐PLTs.Keywords
This publication has 28 references indexed in Scilit:
- Effect of storage time of platelet products on clinical outcomes after transfusion: a systematic review and meta‐analysesVox Sanguinis, 2017
- Why has demand for platelet components increased? A reviewTransfusion Medicine, 2014
- A comparison of adverse reaction rates for PAS C versus plasma platelet unitsTransfusion, 2014
- Replaced platelet concentrates containing a new additive solution, M-sol: safety and efficacy for pediatric patientsTransfusion, 2012
- The impact of apheresis platelet manipulation on corrected count incrementTransfusion, 2012
- A comparison of volume‐reduced versus standard HLA/HPA–matched apheresis platelets in alloimmunized adult patientsTransfusion, 2011
- Prevention of allergic transfusion reactions to platelets and red blood cells through plasma reductionTransfusion, 2011
- Reduction in adverse reactions to platelets by the removal of plasma supernatant and resuspension in a new additive solution (M‐sol)Transfusion, 2009
- The Role of the Plasma from Platelet Concentrates in Transfusion ReactionsNew England Journal of Medicine, 1994
- Prevalence of Platelet Transfusion Reactions Before and After Implementation of Leukocyte-Depleted Platelet Concentrates by FiltrationVox Sanguinis, 1993