Insight into the Contact Impedance between the Electrode and the Skin Surface for Electrophysical Recordings
Open Access
- 14 April 2022
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 7 (16) , 13906-13912
Abstract
To obtain a performance improved dry electrode for bioelectrical activity detection is still a challenge, which is mainly due to the poor fundamental understanding on the impedance of the electrode–skin interface. Herein, the impedance between the electrode and the skin interface of three types of electrodes, which are the wet electrode, semidry electrode, and dry electrode, is investigated with electrochemical impedance spectroscopy combined with the spectra fitting technique. The parameters of performance duration, potential, and frequency associated with the impedance are explored for these three types of electrodes. The overall impedance is roughly constant within the performance duration and the potential applied in this study. Along with the frequency decreases, the impedance of the dry electrode reduces faster and is more complicated compared with the other two types of electrodes. Moreover, the results computed with the equivalent circuits show that the charge transfer resistance is additionally present compared to the wet and semidry electrodes. This large and additional charge transfer resistance may explain its relatively poorer electrophysiological properties.Keywords
Funding Information
- Shenzhen Science and Technology Innovation Commission (KQTD20180413181834876)
- Shenzhen Science and Technology Innovation Committee (JCYJ20170818154035069)
- National Natural Science Foundation of China (62103404)
- SIAT???SZLEDEN Joint Laboratory of Breath Analysis for Biomedical Diagnosis
- Shenzhen Institute of Advanced Technology (E1G028)
- Japan Society for the Promotion of Science (21K15614)
This publication has 40 references indexed in Scilit:
- PEDOT-CNT-Coated Low-Impedance, Ultra-Flexible, and Brain-Conformable Micro-ECoG ArraysIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2014
- History of Electrophysiology and the Patch Clamp2014
- A novel MEMS elastic-based dry electrode for electroencephalography measurementMicrosystem Technologies, 2013
- Design, Fabrication and Experimental Validation of a Novel Dry-Contact Sensor for Measuring Electroencephalography Signals without Skin PreparationSensors, 2011
- New dry electrodes based on iridium oxide (IrO) for non-invasive biopotential recordings and stimulationSensors and Actuators A: Physical, 2010
- Electrophysiology2010
- Evolution in impedance at the electrode-skin interface of two types of surface EMG electrodes during long-term recordingsJournal of Electromyography and Kinesiology, 2003
- Tissue impedance: a historical overviewPhysiological Measurement, 1995
- History and Evolution of Electroencephalographic Instruments and TechniquesJournal Of Clinical Neurophysiology, 1993
- Neurology and the Teaching of MedicineScience, 1928