Technical validity and usability of a novel smartphone‐connected spirometry device for pediatric patients with asthma and cystic fibrosis
Open Access
- 27 June 2020
- journal article
- research article
- Published by Wiley in Pediatric Pulmonology
- Vol. 55 (9) , 2463-2470
Abstract
Background: Diagnosis and follow‐up of respiratory diseases traditionally rely on pulmonary function tests (PFTs), which are currently performed in hospitals and require trained personnel. Smartphone‐connected spirometers, like the Air Next spirometer, have been developed to aid in the home monitoring of patients with pulmonary disease. The aim of this study was to investigate the technical validity and usability of the Air Next spirometer in pediatric patients.Methods: Device variability was tested with a calibrated syringe. About 90 subjects, aged 6 to 16, were included in a prospective cohort study. Fifty‐eight subjects performed conventional spirometry and subsequent Air Next spirometry. The bias and the limits of agreement between the measurements were calculated. Furthermore, subjects used the device for 28 days at home and completed a subject‐satisfaction questionnaire at the end of the study period.Results: Interdevice variability was 2.8% and intradevice variability was 0.9%. The average difference between the Air Next and conventional spirometry was 40 mL for forced expiratory volume in 1 second (FEV1) and 3 mL for forced vital capacity (FVC). The limits of agreement were −270 mL and +352 mL for FEV1 and −403 mL and +397 mL for FVC. About 45% of FEV1 measurements and 41% of FVC measurements at home were acceptable and reproducible according to American Thoracic Society/European Respiratory Society criteria. Parents scored difficulty, usefulness, and reliability of the device 1.9, 3.5, and 3.8 out of 5, respectively.Conclusion: The Air Next device shows validity for the measurement of FEV1 and FVC in a pediatric patient population.Keywords
This publication has 24 references indexed in Scilit:
- Multi-ethnic reference values for spirometry for the 3–95-yr age range: the global lung function 2012 equationsEuropean Respiratory Journal, 2012
- Asthma outcomes: Pulmonary physiologyJournal of Allergy and Clinical Immunology, 2012
- Home telemonitoring (forced expiratory volume in 1 s) in children with severe asthma does not reduce exacerbationsEuropean Respiratory Journal, 2011
- Asthma Control Questionnaire in children: validation, measurement properties, interpretationEuropean Respiratory Journal, 2010
- Primary care spirometry*European Respiratory Journal, 2007
- Technical and Functional Assessment of 10 Office SpirometersChest, 2006
- Home spirometry and asthma severity in childrenEuropean Respiratory Journal, 2006
- Identifying ‘well-controlled’ and ‘not well-controlled’ asthma using the Asthma Control QuestionnaireRespiratory Medicine, 2006
- Determinants of correct inhalation technique in children attending a hospital‐based asthma clinicActa Paediatrica, 2002
- Contributions to Vital Statistics, Obtained by Means of a Pneumatic Apparatus for Valuing the Respiratory Powers with Relation to HealthJournal of the Statistical Society of London, 1844