Successful Percutaneous Trans-Catheter Treatment of Left Ventricular Assist Device Outflow Graft Stenosis with a Covered Stent
Open Access
- 30 April 2015
- journal article
- case report
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 2 (2) , 100-102
Abstract
Case Report Left ventricular assist devices improve survival in patients with advanced heart failure but can be associated with significant complication including infection, pump thrombosis, and de novo severe aortic insufficiency. Outflow graft stenosis is a much more rare complication, but one with significant hemodynamic consequences. Surgical repair is often necessary, but many patients are too high risk for further surgical intervention. We describe the first case of left ventricular assist device outflow graft stenosis treated with percutaneous trans-catheter placement of a covered stent.Keywords
This publication has 6 references indexed in Scilit:
- Treatment of Left Ventricular Assist Device Thrombosis With Extended Catheter-Directed Intraventricular Thrombolytic TherapyCirculation: Heart Failure, 2013
- Fifth INTERMACS annual report: Risk factor analysis from more than 6,000 mechanical circulatory support patientsThe Journal of Heart and Lung Transplantation, 2013
- Percutaneous Transcatheter Aortic Valve Closure Successfully Treats Left Ventricular Assist Device–Associated Aortic Insufficiency and Improves Cardiac HemodynamicsJACC: Cardiovascular Interventions, 2013
- A comparison of covered vs bare expandable stents for the treatment of aortoiliac occlusive diseaseJournal of Vascular Surgery, 2011
- Percutaneous balloon occlusion of a left ventricular assist device outflow cannula to facilitate evaluation of myocardial recoveryThe Journal of Heart and Lung Transplantation, 2011
- Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart FailureThe New England journal of medicine, 2001