Real-Time Cuffless Continuous Blood Pressure Estimation Using 1D Squeeze U-Net Model: A Progress toward mHealth
Open Access
- 18 August 2022
- journal article
- research article
- Published by MDPI AG in Biosensors
- Vol. 12 (8) , 655
Abstract
Measuring continuous blood pressure (BP) in real time by using a mobile health (mHealth) application would open a new door in the advancement of the healthcare system. This study aimed to propose a real-time method and system for measuring BP without using a cuff from a digital artery. An energy-efficient real-time smartphone-application-friendly one-dimensional (1D) Squeeze U-net model is proposed to estimate systolic and diastolic BP values, using only raw photoplethysmogram (PPG) signal. The proposed real-time cuffless BP prediction method was assessed for accuracy, reliability, and potential usefulness in the hypertensive assessment of 100 individuals in two publicly available datasets: Multiparameter Intelligent Monitoring in Intensive Care (MIMIC-I) and Medical Information Mart for Intensive Care (MIMIC-III) waveform database. The proposed model was used to build an android application to measure BP at home. This proposed deep-learning model performs best in terms of systolic BP, diastolic BP, and mean arterial pressure, with a mean absolute error of 4.42, 2.25, and 2.56 mmHg and standard deviation of 4.78, 2.98, and 3.21 mmHg, respectively. The results meet the grade A performance requirements of the British Hypertension Society and satisfy the AAMI error range. The result suggests that only using a short-time PPG signal is sufficient to obtain accurate BP measurements in real time. It is a novel approach for real-time cuffless BP estimation by implementing an mHealth application and can measure BP at home and assess hypertension.Keywords
Funding Information
- National Research Foundation of Korea (2016R1A5A1012966, 2021R1F1A1062285)
This publication has 44 references indexed in Scilit:
- Development of a wireless blood pressure measuring device with smart mobile deviceComputer Methods and Programs in Biomedicine, 2016
- Screening for High Blood Pressure in Adults: U.S. Preventive Services Task Force Recommendation StatementAnnals of Internal Medicine, 2015
- Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and PracticeIEEE Transactions on Biomedical Engineering, 2015
- An Armband Wearable Device for Overnight and Cuff-Less Blood Pressure MeasurementIEEE Transactions on Biomedical Engineering, 2014
- Systolic Peak Detection in Acceleration Photoplethysmograms Measured from Emergency Responders in Tropical ConditionsPLOS ONE, 2013
- The Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood PressureThe JNC 7 ReportJAMA, 2003
- PhysioBank, PhysioToolkit, and PhysioNetCirculation, 2000
- Use of pulse transit time as a measure of inspiratory effort in patients with obstructive sleep apnoeaEuropean Respiratory Journal, 1995
- Short report: An outline of the revised British Hypertension Society protocol for the evaluation of blood pressure measuring devicesJournal Of Hypertension, 1993
- National standard for measurement of resting and ambulatory blood pressures with automated sphygmomanometers.Hypertension, 1993