Ultrasensitive Detection of Surface‐Confined Redox Molecules by Mediation‐Based Amplification
- 27 April 2021
- journal article
- research article
- Published by Wiley in ChemElectroChem
- Vol. 8 (10) , 1873-1880
Abstract
Trace‐level quantification of redox molecules on electrode surfaces is of great importance in multiple fields, including in electrocatalysis and sensing. Using the classical ferrocene/ferrocyanide redox‐mediation‐based electrochemical amplification method as a proof of concept, ferrocene‐terminated alkanethiols, embedded in alkanethiol‐based self‐assembled monolayers, were quantified at levels approaching 10−14 mol cm−2 (ca. 60 molecules per square micron) by combining experimental (cyclic voltammetry) and computational (digital simulation of voltammetric behavior) approaches. Quantification at these ultra‐low ferrocene surface coverages was achieved via simulated calibration curves of the ferrocyanide oxidation peak potential vs log(ferrocene thiol surface coverage) that extend the limit for immobilized ferrocene quantification by more than an order of magnitude relative to the smallest amount that can be reliably quantified by integration of the ferrocene oxidation/reduction peaks in a supporting electrolyte by monolayer cyclic voltammetry. The simulations provide important clues regarding which monolayer property changes could be expected to further extend the detection limit of immobilized redox molecules.Keywords
This publication has 24 references indexed in Scilit:
- Enhanced Signal Amplification in a Toll-like Receptor-4 Biosensor Utilizing Ferrocene-Terminated Mixed MonolayersACS Sensors, 2018
- Foot of the Wave Analysis for Mechanistic Elucidation and Benchmarking Applications in Molecular Water Oxidation CatalysisChemSusChem, 2016
- Multi‐Level Logic Gate Operation Based on Amplified Aptasensor PerformanceAngewandte Chemie International Edition, 2015
- Logisches Mehrschrittgatter auf Basis eines Aptamersensors mit verstärktem SensorsignalAngewandte Chemie, 2015
- Electrochemical current rectification–a novel signal amplification strategy for highly sensitive and selective aptamer-based biosensorBiosensors and Bioelectronics, 2015
- The Mechanism of Mediated Electron Transfer at Redox Active SurfacesElectroanalysis, 2015
- Cathodic catalysts in bioelectrochemical systems for energy recovery from wastewaterChemical Society Reviews, 2013
- Dual oxygen and Ir oxide regeneration of glucose oxidase in nanostructured thin film glucose sensorsElectrochimica Acta, 2010
- Reversible interconversion of carbon dioxide and formate by an electroactive enzymeProceedings of the National Academy of Sciences of the United States of America, 2008
- Signal Enhancement for Gene Detection Based on a Redox Reaction of [Fe(CN)6]4– Mediated by Ferrocene at the Terminal of a Peptide Nucleic Acid as a Probe with Hybridization-amenable Conformational FlexibilityAnalytical Sciences, 2008