New method for noninvasive measurement of utility harmonic impedance
- 1 July 2012
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19325517,p. 1-8
Abstract
The new, noninvasive method of measurement for power system harmonic impedance is presented in the paper. The method is based on the observation of variations of voltage and current harmonics caused by natural load variability. The novelty of the method lays in a way the method rejects segments of data containing insufficient or false information about the identified power system. Segment selection/rejection uses logical conditions applied to RMS values of measured voltage and current. Harmonic impedance of the power grid is then calculated using modified power spectral method. The method was validated in a field test conducted at 30 kV feeder bus of HV/MV substation. Details of the experiment and the results are discussed the paper. Obtained results confirm that the method copes with temporal, band-limited excitation as well as with deep, sudden changes of utility background voltage.Keywords
This publication has 18 references indexed in Scilit:
- Improvement of Accuracy of Power System Spectral Analysis by Coherent ResamplingIEEE Transactions on Power Delivery, 2009
- Constant power loads in AC distribution systems: An investigation of stability2008
- A Phase-Locked Loop for the Synchronization of Power Quality Instruments in the Presence of Stationary and Transient DisturbancesIEEE Transactions on Instrumentation and Measurement, 2007
- A New Method for Statistical Assessment of the System Harmonic Impedance and of the Background Voltage Distortion2006
- Measurement of harmonics/inter-harmonics of time-varying frequenciesIEEE Transactions on Power Delivery, 2005
- Power System Harmonics2003
- On-line measurement of equivalent parameters of distribution system and its load for harmonic frequencies2002
- Measurement of network harmonic impedances: practical implementation issues and their solutionsIEEE Transactions on Power Delivery, 2002
- A low-cost frequency multiplier for synchronous sampling of periodic signalsIEEE Transactions on Instrumentation and Measurement, 1992
- The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodogramsIEEE Transactions on Audio and Electroacoustics, 1967