Rotating Brush for Fast Removal of Corneal Epithelium
Authors:
- Athanase D KaroutisAKAthanase D Karoutis
- Stella E LydatakiSLStella E Lydataki
- Dimitrios S SiganosDSDimitrios S Siganos
- 1 July 1994
- journal article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 10 (4) , 439-442
Abstract
BACKGROUND: A simple new device is proposed for safe and very fast epithelial removal of the cornea. This is a rotating plastic brush that removes the corneal epithelium within a few seconds under irrigation, without causing any mechanical damage to the stromal surface. METHODS: Comparative SEM and TEM studies on rabbit corneas were carried out following epithelial removal by rotating brush and by a Beaver knife blade. Epithelial removal time and reepithelialization time after photorefractive keratectomy were evaluated in a series of 40 human sighted eyes treated with the brush. RESULTS: The rotating brush-abraded surface was smoother compared to the blade-abraded one. Additionally, the brush provoked no damage to the basal lamina of the rabbit corneal epithelium. In human photorefractive keratectomy, the mean time needed for removal of the corneal epithelium by the rotating brush was only 3 sec (range, 2-5 sec). Reepithelialization time following photorefractive keratectomy did not exceed 3 days. CONCLUSION: Experimental and preliminary clinical studies suggest that the new rotating plastic brush is a safe and fast method for removing the corneal epithelium. [J Refract Corneal Surg. 1994;10:439-442.]Keywords
This publication has 12 references indexed in Scilit:
- LASER EPITHELIUM REMOVAL BEFORE PHOTOREFRACTIVE KERATECTOMYJournal of Refractive Surgery, 1993
- Optics of the Corneal EpitheliumJournal of Refractive Surgery, 1993
- Corneal epithelium, visual acuity, and laser refractive keratectomy1991
- Topography and Raytracing Analysis of Patients With Excellent Visual Acuity 3 Months After Excimer Laser Photorefractive Keratectomy for MyopiaJournal of Refractive Surgery, 1991
- Myopic Excimer Laser Keratectomy: A Preliminary ReportJournal of Refractive Surgery, 1990
- Excimer Laser (193 nm) Myopic Keratomileusis in Sighted and Blind Human EyesJournal of Refractive Surgery, 1990
- Ablation Rate of Human Corneal Epithelium and Bowman's Layer With the Excimer Laser (193 nm)Journal of Refractive Surgery, 1990
- Experimental corneal studies with the excimer laserJournal of Cataract & Refractive Surgery, 1989
- Human Excimer Laser Lamellar KeratectomyOphthalmology, 1989
- Excimer Laser Keratectomy for Correction of AstigmatismAmerican Journal of Ophthalmology, 1988