Melanoma histological Breslow thickness predicted by 75-MHz ultrasonography
- 1 August 2008
- journal article
- research article
- Published by Oxford University Press (OUP) in British Journal of Dermatology
- Vol. 159 (2) , 364-369
Abstract
Ultrasound at 20 MHz tends to overestimate melanoma Breslow thickness due to lymphocytic infiltration or naevus remnant. Objectives To determine the efficacy of 75-MHz ultrasound for estimating melanoma thickness and to assess its reliability to predict surgical requirement. One hundred and twelve suspicious skin lesions were imaged prospectively with the 75-MHz ultrasound in A and B mode. This instrument has a penetration of 3 mm and a lateral resolution of 21 mum. Measurements were performed by two observers and the mean was compared with the histological Breslow thickness. Forty-five of 52 melanomas and 22 of 36 naevi had clear hypoechogenicity boundaries. The median histological Breslow thickness of melanomas was 0.4 mm and 22 were in situ. The median percentage error of the machine was 13% of the histological Breslow thickness, with a high correlation (Pearson's r = 0.908, P < 0.001). Measurement was highly reliable for invasive melanoma, even in the presence of lymphocytic infiltration or naevus. In this series, 75-MHz measurement was highly reliable for predicting invasive melanoma thickness.Keywords
This publication has 18 references indexed in Scilit:
- The Impact of In Vivo Reflectance Confocal Microscopy for the Diagnostic Accuracy of Melanoma and Equivocal Melanocytic LesionsJournal of Investigative Dermatology, 2007
- Ultrasound contrast agents: An overviewEuropean Journal of Radiology, 2006
- Dynamic assessment of antiangiogenic therapy by monitoring both tumoral vascularization and tissue degenerationGene Therapy, 2006
- Clinical relevance of sonometry-derived tumour thickness in malignant melanoma-a statistical analysisBritish Journal of Dermatology, 2006
- Prognostic value of angiogenesis evaluated with high-frequency and colour Doppler sonography for preoperative assessment of primary cutaneous melanomas: correlation with recurrence after a 5 year follow-up periodCancer Imaging, 2006
- Limitations of high frequency ultrasound in determining the invasiveness of cutaneous malignant melanomaMelanoma Research, 1996
- Influence of skin tension and formalin fixation on sonographic measurement of tumor thicknessJournal of the American Academy of Dermatology, 1996
- High frequency, high resolution B-scan ultrasound in the assessment of skin tumoursBritish Journal of Dermatology, 1993
- Malignant Melanoma in 20-MHz B Scan SonographyDermatology, 1992
- Ultrasonographic measurement of uveal melanoma thickness: interobserver variability.British Journal of Ophthalmology, 1990