MR imaging of the female pelvis at 3 Tesla: Evaluation of image homogeneity using different dielectric pads
Authors:
Open Access
- 29 October 2007
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 26 (6) , 1572-1577
Abstract
Purpose: To evaluate improvements in image homogeneity in pelvic MR imaging at 3 Tesla (T) using two different dielectric pads.Materials and Methods: A total of eight healthy females were scanned using a 3T MR scanner equipped with a body‐array coil. Axial and sagittal fast spin‐echo T2‐weighted images (T2WI) (TR/TE = 3200 msec/94 msec), axial fast spin‐echo T1‐weighted images (T1WI) (TR/TE = 700 msec/11 msec), and sagittal half‐Fourier acquisition single‐shot turbo spin‐echo (HASTE) images (TR/TE = 3000 msec/100 msec) were performed for pelvic imaging. Sequences were repeated with dielectric pads (consisting of either ultrasound [US] gel or water), and without pads. Three or four regions of interest (ROIs) were placed on fatty tissues and the ratio of minimum to maximum signal intensity (RSI) was calculated as a marker of image homogeneity.Results: RSI was significantly higher on T2WI and T1WI when using dielectric pads than when no pad was used. A similar tendency was observed in RSI on HASTE. No significant difference was found between images with US gel pads and those with water pads.Conclusion: Dielectric pads consisting of either US gel or water are effective in improving image homogeneity of the pelvis on 3T MRI. J. Magn. Reson. Imaging 2007.Keywords
This publication has 17 references indexed in Scilit:
- A simple solution for reducing artefacts due to conductive and dielectric effects in clinical magnetic resonance imaging at 3TEuropean Journal of Radiology, 2007
- Manipulation of image intensity distribution at 7.0 T: Passive RF shimming and focusing with dielectric materialsJournal of Magnetic Resonance Imaging, 2006
- Abdominal MRI at 3.0 T: The Basics RevisitedAmerican Journal of Roentgenology, 2006
- Dysmenorrhea: Evaluation with Cine-Mode-Display MR Imaging—Initial ExperienceRadiology, 2005
- Acute and Subacute Ischemic Stroke at High-Field-Strength (3.0-T) Diffusion-weighted MR Imaging: Intraindividual Comparative StudyRadiology, 2005
- Whole-body MRI at high field: technical limits and clinical potentialEuropean Radiology, 2005
- Coronary arteries at 3.0 T: Contrast‐enhanced magnetization‐prepared three‐dimensional breathhold MR angiographyJournal of Magnetic Resonance Imaging, 2005
- Coronary artery wall imaging: Initial experience at 3 TeslaJournal of Magnetic Resonance Imaging, 2005
- Reduction of wave phenomena in high-field MRI experiments using absorbing layersJournal of Magnetic Resonance, 2004
- Time-of-Flight MR Angiography: Comparison of 3.0-T Imaging and 1.5-T Imaging—Initial ExperienceRadiology, 2003