Dynamic pH junction–sweeping for on-line focusing of dipeptides in capillary electrophoresis with laser-induced fluorescence detection
- 11 March 2011
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 136 (9) , 1852-1858
Abstract
In this paper, we developed a simple and effective on-line focusing technique combining dynamic pH junction and sweeping by capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection. Dynamic pH junction–sweeping is defined when the sample has a different buffer pH (dynamic pH junction condition) and is devoid of micelles (sweeping condition) relative to the background electrolyte (BGE). This hyphenated focusing mode was applied to the sensitive and selective focusing of four dipeptides: Tyr–Phe, Tyr–Leu, Trp–Gly, and Ala–Gln. Picomolar detectability of these dipeptides by CE–LIF detection was demonstrated through effective focusing of large sample volumes (up to 39% capillary length) using the dual pH junction-sweeping focusing mode. 25 mmol L−1sodium dihydrogen phosphate, pH 2.5 was used as the sample matrix, and 100 mmol L−1borate, 21 mmol L−1sodium dodecylsulfate (SDS), 16 mmol L−1 Brij35, pH 9.0 as the background solution (BGS). The concentration detection limits (S/N = 3) of the four dipeptides were in the range of 1.0–5.0 pmol L−1. The developed method has been successfully used for the determination of dipeptides in human serum samples.Keywords
This publication has 34 references indexed in Scilit:
- Optimization of Field-Amplified Sample Injection for Analysis of Peptides by Capillary Electrophoresis−Mass SpectrometryAnalytical Chemistry, 2006
- Applications of capillary electrophoresis to high-sensitivity analyses of biomoleculesPure and Applied Chemistry, 2006
- High-Resolution Computer Simulations of Stacking of Weak Bases Using a Transient pH Boundary in Capillary Electrophoresis. 1. Concept and Impact of Sample Ionic StrengthAnalytical Chemistry, 2005
- Quantitative Predictions to Conditions of Zwitterionic Stacking by Transient Moving Chemical Reaction Boundary Created with Weak Electrolyte Buffers in Capillary ElectrophoresisAnalytical Chemistry, 2005
- Over 1000-fold protein preconcentration for microliter-volume samples at a pH junction using capillary electrophoresisJournal of Chromatography A, 2004
- Field-enhanced sample injection for high-sensitivity analysis of peptides and proteins in capillary electrophoresis–mass spectrometryJournal of Chromatography A, 2004
- Mechanistic Study on Analyte Focusing by Dynamic pH Junction in Capillary Electrophoresis Using Computer SimulationAnalytical Chemistry, 2003
- A robust approach for the analysis of peptides in the low femtomole range by capillary electrophoresis-tandem mass spectrometryElectrophoresis, 2002
- Stacking Ionizable Analytes in a Sample Matrix with High Salt by a Transient Moving Chemical Reaction Boundary Method in Capillary Zone ElectrophoresisAnalytical Chemistry, 2002
- On-Line Focusing of Flavin Derivatives Using Dynamic pH Junction-Sweeping Capillary Electrophoresis with Laser-Induced Fluorescence DetectionAnalytical Chemistry, 2002