Biomechanical Determination of Distal Level for Fusions across the Cervicothoracic Junction
Authors:
Open Access
- 11 February 2015
- journal article
- Published by SAGE Publications in Global Spine Journal
- Vol. 5 (4) , 282-286
Abstract
Study Design: In vitro testing. Objective: To determine whether long cervical and cervicothoracic fusions increase the intradiscal pressure at the adjacent caudal disk and to determine which thoracic end vertebra causes the least increase in the adjacent-level intradiscal pressure. Methods: A bending moment was applied to six cadaveric cervicothoracic spine specimens with intact rib cages. Intradiscal pressures were recorded from C7–T1 to T9–10 before and after simulated fusion by anterior cervical plating and posterior thoracic pedicle screw constructs. The changes in the intradiscal pressure from baseline were calculated and compared. Results: No significant differences where found when the changes of the juxtafusion intradiscal pressure at each level were compared for the flexion, extension, and left and right bending simulations. However, combining the pressures for all directions of bending at each level demonstrated a decrease in the pressures at the T2–T3 level. Exploratory analysis comparing changes in the pressure at T2–T3 to other levels showed a significant decrease in the pressures at this level ( p = 0.005). Conclusions: Based on the combined intradiscal pressures alone it may be advantageous to end long constructs spanning the cervicothoracic junction at the T2 level if there are no other mitigating factors.Keywords
This publication has 22 references indexed in Scilit:
- Reoperations in Cervical Total Disc Replacement Compared With Anterior Cervical FusionSpine, 2013
- Adjacent Segment Disease Following Cervical Spine SurgeryJournal of the American Academy of Orthopaedic Surgeons, 2012
- What are the associative factors of adjacent segment degeneration after anterior cervical spine surgery? Comparative study between anterior cervical fusion and arthroplasty with 5-year follow-up MRI and CTEuropean Spine Journal, 2012
- Adjacent Segment Pathology Following Cervical Motion-Sparing Procedures or Devices Compared With Fusion SurgerySpine, 2012
- Cervical artificial disc replacement versus fusion in the cervical spine: a systematic review comparing long-term follow-up results from two FDA trialsEvidence-Based Spine-Care Journal, 2012
- Effect of lower two-level anterior cervical fusion on the superior adjacent levelJournal of Neurosurgery: Spine, 2007
- The Role of the Sternum, Costosternal Articulations, Intervertebral Disc, and Facets in Thoracic Sagittal Plane BiomechanicsSpine, 2005
- Biomechanical Study on the Effect of Cervical Spine Fusion on Adjacent-Level Intradiscal Pressure and Segmental MotionSpine, 2002
- Radiculopathy and Myelopathy at Segments Adjacent to the Site of a Previous Anterior Cervical Arthrodesis*Journal of Bone and Joint Surgery, 1999
- Modified Smith-Robinson Procedure for Anterior Cervical Discectomy and FusionSpine, 1992