Comparing Total Keratometry Measurement on the IOLMaster 700 With Goggin Nomogram Adjusted Anterior Keratometry
Authors:
- Benjamin R. LaHoodBLBenjamin R. LaHood
- Michael GogginMGMichael Goggin
- Simone BeheregaraySBSimone Beheregaray
- Nicholas H. AndrewNANicholas H. Andrew
- Adrian EstermanAEAdrian Esterman
- 1 August 2018
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 34 (8) , 521-526
Abstract
PURPOSE: To compare “total keratometry” measurements with Goggin nomogram adjusted anterior keratometry (GNAK) for toric intraocular lens calculation. METHODS: Routine biometry provided measured total keratometry values from which astigmatism was derived. The Goggin nomogram was applied to anterior keratometry values on the same eyes to provide nomogram-adjusted anterior keratometry values (GNAK) that estimate total corneal astigmatism. The agreement between total keratometry and GNAK was analyzed. RESULTS: Overall, in 46 eyes there was no statistically significant difference between median GNAK and total keratometry power values ( P = .746). No statistically significant difference remained in against-the-rule and oblique subgroup analyses. Absolute and signed steep axis of astigmatism was statistically significantly different for GNAK and total keratometry in the overall analysis ( P < .001 and = .029, respectively) and for against-the-rule and oblique subgroup analyses. The with-the-rule subgroup showed a statistically significant difference in astigmatic power and no significant signed steep axis difference between GNAK and total keratometry. CONCLUSIONS: Total keratometry appears able to measure total corneal astigmatism to match closely (clinically and statistically) GNAK estimation of that parameter. This indicates that it would be safe and reasonable to use total keratometry data for planning of cataract surgery with toric IOLs. [ J Refract Surg. 2018;34(8):521–526.]Keywords
This publication has 16 references indexed in Scilit:
- Measurement of Posterior Corneal Astigmatism by the IOLMaster 700Journal of Refractive Surgery, 2018
- Assessing the Likely Effect of Posterior Corneal Curvature on Toric IOL Calculation for IOLs of 2.50 D or Greater Cylinder PowerJournal of Refractive Surgery, 2017
- Outcome of adjustment for posterior corneal curvature in toric intraocular lens calculation and selectionJournal of Cataract & Refractive Surgery, 2016
- Comparison of Anterior Segment Measurements between Dual and Single Scheimpflug CameraJournal of the Korean Ophthalmological Society, 2016
- Adjustment of Anterior Corneal Astigmatism Values to Incorporate the Likely Effect of Posterior Corneal Curvature for Toric Intraocular Lens CalculationJournal of Refractive Surgery, 2015
- Distribution of Posterior Corneal Astigmatism According to Axis Orientation of Anterior Corneal AstigmatismPLOS ONE, 2015
- An Analysis of the Factors Influencing the Residual Refractive Astigmatism After Cataract Surgery With Toric Intraocular LensesInvestigative Ophthalmology & Visual Science, 2015
- Contribution of posterior corneal astigmatism to total corneal astigmatismJournal of Cataract & Refractive Surgery, 2012
- Accuracy of Corneal Astigmatism Estimation by Neglecting the Posterior Corneal Surface MeasurementAmerican Journal of Ophthalmology, 2009
- Intrasession and intersession repeatability of the Pentacam system on posterior corneal assessment in the normal human eyeJournal of Cataract & Refractive Surgery, 2007