Arm Raising at Exposure-controlled Multidetector Trauma CT of Thoracoabdominal Region: Higher Image Quality, Lower Radiation Dose
Authors:
- Monique BrinkMBMonique Brink
- Frank de LangeFLFrank de Lange
- Luuk J. OostveenLOLuuk J. Oostveen
- Helena M. DekkerHDHelena M. Dekker
- Digna R. KoolDKDigna R. Kool
- Jaap DeunkJDJaap Deunk
- Michael J. R. EdwardsMEMichael J. R. Edwards
- Cornelis van KuijkCKCornelis van Kuijk
- Richard L. KammanRKRichard L. Kamman
- Johan G. BlickmanJBJohan G. Blickman
- 1 November 2008
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 249 (2) , 661-670
Abstract
To evaluate the effect of arm position on image quality and effective radiation dose in an automatic exposure-controlled (AEC) multidetector thoracoabdominal computed tomography (CT) protocol in trauma patients. This retrospective study of the data of 177 trauma patients (117 male; median age, 39 years) was approved by the institutional ethics board, with informed patient consent waived. Patients underwent scanning by using an AEC 16-detector thoracoabdominal CT protocol in which both arms were raised above the shoulder region (standard-position group, 132 patients), one arm was raised and the other was down (one-arm group, 27 patients), or both arms were down (two-arm group, 18 patients). Objective and subjective image quality was assessed. Individual effective radiation dose was calculated from the effective tube current-time product per exposed section. For this purpose, section location-dependent conversion factors were derived by using a CT dosimetry calculator. The effect of arm position on effective dose was quantified by using linear regression analysis with correction for patient volume and attenuation. Compared with the image quality in the standard-position group, the image quality in the one- and two-arm groups was decreased but within acceptable diagnostic limits. The median corrected effective dose in the standard-position group was 18.6 mSv; the dose in the one-arm group was 18% (95% confidence interval: 11%, 25%) higher than this, and that in the two-arm group was 45% (95% confidence interval: 34%, 57%) higher. Omitting arm raising results in lower but acceptable image quality and a substantially higher effective radiation dose. Hence, effort should be made to position the arms above the shoulder when scanning trauma patients. Clinical trial registration no. NCT00228111.Keywords
This publication has 25 references indexed in Scilit:
- Computed Tomography — An Increasing Source of Radiation ExposureThe New England journal of medicine, 2007
- Diagnosis of blunt traumatic aortic injury 2007: Still a nemesisEuropean Journal of Radiology, 2007
- Increasing utilization of computed tomography in the adult emergency department, 2000–2005Emergency Radiology, 2006
- CT Dose Reduction and Dose Management Tools: Overview of Available OptionsRadioGraphics, 2006
- Comparison of Angular and Combined Automatic Tube Current Modulation Techniques with Constant Tube Current CT of the Abdomen and PelvisAmerican Journal of Roentgenology, 2006
- Computed Tomography Radiation Dose Optimization: Scanning Protocols and Clinical Applications of Automatic Exposure ControlCurrent Problems in Diagnostic Radiology, 2005
- CT measurement of coronary calcium mass: impact on global cardiac risk assessmentEuropean Radiology, 2004
- Estimated Radiation Risks Potentially Associated with Full-Body CT ScreeningRadiology, 2004
- Experience with a continuous, single-pass whole-body multidetector CT protocol for trauma: the three-minute multiple trauma CT scanEmergency Radiology, 2001
- Standardized CT examination of the multitraumatized patientEuropean Radiology, 1998