Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes
Authors:
- 1 October 2023
- journal article
- research article
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 18 (10) , P10006
Abstract
Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10-4. LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.Keywords
All Related Versions
This publication has 13 references indexed in Scilit:
- Trench-Isolated Low Gain Avalanche Diodes (TI-LGADs)IEEE Electron Device Letters, 2020
- Use of “LGAD” ultra-fast silicon detectors for time-resolved low-keV X-ray scienceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2019
- Comparison of 35 and m thin HPK UFSD after neutron irradiation up to 6 1015 neq/cm2Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2019
- Recent developments in Geant4Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- Ultra-fast silicon detectors (UFSD)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- Technology developments and first measurements of Low Gain Avalanche Detectors (LGAD) for high energy physics applicationsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- Baseline correction using asymmetrically reweighted penalized least squares smoothingThe Analyst, 2014
- Geometry Description Markup Language for Physics Simulation and Analysis ApplicationsIEEE Transactions on Nuclear Science, 2006
- Geant4 developments and applicationsIEEE Transactions on Nuclear Science, 2006
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003