On the effectiveness of shear reinforcement type in GFRP ‐reinforced concrete beams: Experimental study
Authors:
Open Access
- 21 April 2025
- journal article
- Published by Wiley in Structural Concrete
- Vol. 26 (5) , 6547-6575
Abstract
This study investigated the shear performance of concrete beams with GFRP stirrups vs. traditional steel stirrups. Longitudinal glass fiber‐reinforced polymer (GFRP) bars were used to doubly reinforce the tested beams at both the top and bottom of their cross sections. To accomplish this, several stirrup spacings were provided. Eight beam specimens, measuring 300 × 250 × 2400 mm, were used in an experimental program to test under a two‐point concentrated load with an equal span‐to‐depth ratio until failure. Four beams in Group I have standard mild steel stirrups of 8 mm diameter, while four beams in Group II have GFRP stirrups with the same adopted diameter. The difference between the beams in each group was mainly due to the spacing between the reinforcing stirrups in the constant shear and pure bending spans. The test matrix consists of two beams with shear reinforcement equally distributed at 100 mm and 200 mm in constant shear and pure bending spans, respectively. Stirrups were placed uniformly over the whole effective span of the other six beams. In two beams, stirrups were placed 100 mm apart; in the other two, 75 mm; and in the last two, 50 mm. Test outcomes showed that GFRP stirrups, as opposed to steel stirrups, decreased the ultimate load by around 8%–27% based on stirrup spacing, while reducing the stirrup spacing increased the shear capacity. Also, the presence of compression GFRP bars and GFRP stirrups in the pure bending span led to an increase in the flexural stiffness of the tested beams. Consequently, this increase contributed to a higher ductility index. Accordingly, it is essential to prioritize adequate shear strength above flexural strength when designing GFRP‐reinforced concrete beams, as evidenced by the continuous observation of flexure‐shear cracking as the primary mode of failure in almost all tested beams.Keywords
This publication has 50 references indexed in Scilit:
- Shear strengthening of RC beams with prestressed NSM CFRP: Influencing factors and analytical modelComposite Structures, 2024
- Experimental study on shear performance of PET FRP-strengthened RC beams without stirrupsCase Studies in Construction Materials, 2024
- Shear performance of glass fiber reinforced concrete beams with diverse embedded GFRP trussesCase Studies in Construction Materials, 2023
- Analysis of circular concrete members reinforced with composite glass-FRP spiralsComposite Structures, 2022
- Study on the shear behavior of RC beams strengthened by CFRP grid with epoxy mortarComposite Structures, 2021
- Experimental and analytical shear evaluation of concrete beams reinforced with glass fiber reinforced polymers barsConstruction and Building Materials, 2016
- Flexural behaviors of hybrid concrete beams reinforced with BFRP bars and steel barsConstruction and Building Materials, 2015
- Shear design of reinforced concrete beams with FRP longitudinal and transverse reinforcementComposites Part B: Engineering, 2015
- Bond–slip behaviour of FRP-reinforced concrete beamsConstruction and Building Materials, 2013
- Shear capacity of concrete beams reinforced with fiber reinforced polymersComposite Structures, 2005