High-Performance FPGA Architecture for Multi-line Beamforming in Ultrasound Applications
- 27 October 2016
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 51, 584-590
Abstract
Nowadays, several applications are requested to process huge amount of data with tight temporal constraints to produce "real time" results. This is the case of ultrasound (US) tomographic (B-mode) images used in diagnostics. A B-mode image is typically composed by many tens of vertical lines. Each line is calculated by the so-called beamformer (BF) that combines the echoes received from tens of small piezoelectric transducers integrated in the US probe. The BF processes massive quantity of data (several Gb/s) and is implemented in fast digital devices like the FPGAs. In the standard approach, the B-mode image is formed on a line-by-line basis, i.e. one line per pulse repetition interval (PRI). This limits the achievable image frame rate (IFR) to few tens of Hz, which is not suitable to detail fast, important phenomena like the heart valve movement. In the so-called plane-wave approach, the data needed to produce all of the B-mode image lines are acquired in a single PRI. In this case, the IFR can be in the order of kHz, but a more complex BF is needed. In this paper, we present a Multi-Line BF architecture, capable of real-time processing tens of lines per PRI. The BF was implemented in the research ultrasound system ULA-OP 256. A sample B-mode sequence obtained at IFR = 600Hz is presented.Keywords
This publication has 13 references indexed in Scilit:
- ULA-OP 256: A 256-Channel Open Scanner for Development and Real-Time Implementation of New Ultrasound MethodsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2016
- Software-based high-level synthesis design of FPGA beamformers for synthetic aperture imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2015
- Comparison of Carotid Artery Blood Velocity Measurements by Vector and Standard Doppler ApproachesUltrasound in Medicine & Biology, 2015
- SARUS: A synthetic aperture real-time ultrasound systemIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2013
- A reconfigurable and programmable FPGA-based system for nonstandard ultrasound methodsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2012
- GPU-based beamformer: Fast realization of plane wave compounding and synthetic aperture imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2011
- Multichannel FPGA-based arbitrary waveform generator for medical ultrasoundElectronics Letters, 2007
- Compact FPGA-based beamformer using oversampled 1-bit A/D convertersIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2005
- VLSI circuits for adaptive digital beamforming in ultrasound imagingIEEE Transactions on Medical Imaging, 1993
- Digital beamforming in ultrasoundIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1992