Bacterial contamination of platelet concentrates prepared by different methods: results of standardized sterility testing in Germany
- 28 February 2006
- journal article
- research article
- Published by Wiley in Vox Sanguinis
- Vol. 90 (3) , 177-182
Abstract
Background and Objectives National guidelines for monitoring the bacterial contamination rate of blood components were introduced in Germany in 1997. The objective of this study was to present and evaluate the results of sterility testing of platelet concentrates (PCs) prepared by different methods.Materials and Methods The analysis of results of sterility testing of blood component production from transfusion medicine centres in Germany in 1998 and 2001 was based on information collected using standardized questionnaires.Results The bacterial contamination rates for single‐donor PCs derived from whole blood and apheresis (0·210% vs. 0·156%) were comparable and showed no significant difference. However, pooled PCs produced from four buffy coats using the sterile docking procedure showed a significantly higher bacterial contamination rate compared with single‐donor PCs derived from whole blood and apheresis (0·184% vs. 0·604%).Conclusions Use of standardized methods for sterility monitoring is sufficient to assess collection and production processes in terms of hygiene and yields reliable data on bacterial contamination rates of blood components. The methods described are suitable for using to analyse the efficiency of newly introduced methods to reduce bacterial contamination rates of blood components (e.g. diversion, bacteria screening and pathogen inactivation).Keywords
This publication has 15 references indexed in Scilit:
- Transfusion‐transmitted bacterial infection: risks, sources and interventionsVox Sanguinis, 2004
- ORIGINAL PAPER. Relative values of the interventions of diversion and improved donor‐arm disinfection to reduce the bacterial risk from blood transfusionVox Sanguinis, 2004
- Improving the bacteriological safety of platelet transfusionsTransfusion Medicine Reviews, 2004
- Hämovigilanz in Deutschland – Berichte an das Paul-Ehrlich-Institut über Verdachtsfälle von Transfusionsreaktionen im Beobachtungszeitraum Januar 1995 bis Dezember 2002Transfusion Medicine and Hemotherapy, 2003
- The RHCE allele ceRT: D epitope 6 expression does not require D‐specific amino acidsTransfusion, 2003
- Operational feasibility of routine bacterial monitoring of plateletsTransfusion Medicine, 2003
- Transfusion‐transmitted bacterial infectionin the United States, 1998 through 2000Transfusion, 2001
- Determinants of transfusion‐associated bacterial contamination: results of the French Bacthem Case‐Control StudyTransfusion, 2001
- A retrospective analysis of microbial contaminants in outdated random‐donor platelets from multiple sitesTransfusion, 1997
- Bacterial contamination of platelet concentrates stored at 20°CJournal of Clinical Pathology, 1973