Point-of-Care Versus Central Laboratory Measurements of Hemoglobin, Hematocrit, Glucose, Bicarbonate and Electrolytes: A Prospective Observational Study in Critically Ill Patients
Open Access
- 10 January 2017
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (1) , e0169593
Abstract
Rapid detection of abnormal biological values using point-of-care (POC) testing allows clinicians to promptly initiate therapy; however, there are concerns regarding the reliability of POC measurements. We investigated the agreement between the latest generation blood gas analyzer and central laboratory measurements of electrolytes, bicarbonate, hemoglobin, hematocrit, and glucose. 314 paired samples were collected prospectively from 51 critically ill patients. All samples were drawn simultaneously in the morning from an arterial line. BD Vacutainer tubes were analyzed in the central laboratory using Beckman Coulter analyzers (AU 5800 and DxH 800). BD Preset 3 ml heparinized-syringes were analyzed immediately in the ICU using the POC Siemens RAPIDPoint 500 blood gas system. We used CLIA proficiency testing criteria to define acceptable analytical performance and interchangeability. Biases, limits of agreement (±1.96 SD) and coefficients of correlation were respectively: 1.3 (-2.2 to 4.8 mmol/L, r = 0.936) for sodium; 0.2 (-0.2 to 0.6 mmol/L, r = 0.944) for potassium; -0.9 (-3.7 to 2 mmol/L, r = 0.967) for chloride; 0.8 (-1.9 to 3.4 mmol/L, r = 0.968) for bicarbonate; -11 (-30 to 9 mg/dL, r = 0.972) for glucose; -0.8 (-1.4 to -0.2 g/dL, r = 0.985) for hemoglobin; and -1.1 (-2.9 to 0.7%, r = 0.981) for hematocrit. All differences were below CLIA cut-off values, except for hemoglobin. Compared to central Laboratory analyzers, the POC Siemens RAPIDPoint 500 blood gas system satisfied the CLIA criteria of interchangeability for all tested parameters, except for hemoglobin. These results are warranted for our own procedures and devices. Bearing these restrictions, we recommend clinicians to initiate an appropriate therapy based on POC testing without awaiting a control measurement.Keywords
This publication has 40 references indexed in Scilit:
- Clinical review: Consensus recommendations on measurement of blood glucose and reporting glycemic control in critically ill adultsCritical Care, 2013
- Use of a blood gas analyzer and a laboratory autoanalyzer in routine practice to measure electrolytes in intensive care unit patientsBMC Anesthesiology, 2012
- Electrolytes assessed by point-of-care testing - Are the values comparable with results obtained from the central laboratory?Indian Journal of Critical Care Medicine, 2011
- International Council for Standardization in Haematology technical report 1‐2009: new reference material for haemiglobincyanide for use in standardization of blood haemoglobin measurementsInternational Journal of Laboratory Hematology, 2010
- Fluid and Electrolyte Disturbances in Critically Ill PatientsElectrolytes & Blood Pressure, 2010
- Intensive versus Conventional Glucose Control in Critically Ill PatientsThe New England journal of medicine, 2009
- Comparison of the point-of-care blood gas analyzer versus the laboratory auto-analyzer for the measurement of electrolytesInternational Journal of Emergency Medicine, 2009
- Management of Hyperglycemia in the Hospital SettingNew England Journal of Medicine, 2006
- Assessing Acid-Base Status in Circulatory Failure. Differences Between Arterial and Central Venous BloodSurvey of Anesthesiology, 1989
- Assessing Acid-Base Status in Circulatory FailureThe New England journal of medicine, 1989