Induced Voltage Linear Extraction Method Using an Active Kelvin Bridge for Disturbing Force Self-Sensing
Open Access
Abstract
This paper presents an induced voltage linear extraction method for disturbing force self-sensing in the application of giant magnetostrictive actuators (GMAs). In this method, a Kelvin bridge combined with an active device is constructed instead of a conventional Wheatstone bridge for extraction of the induced voltage, and an additional GMA is adopted as a reference actuator in the self-sensing circuit in order to balance the circuit bridge. The linear fitting of the measurement data is done according to the linear relationship between the disturbing forces and the integral of the induced voltage. The experimental results confirm the good performance of the proposed method, and the self-sensitivity of the disturbing forces is better than 2.0 (mV·s)/N.Keywords
Funding Information
- National Natural Science Foundation Grants (51375121, 50905046)
This publication has 17 references indexed in Scilit:
- Investigation ofEffect on Vibrational Behavior of Giant Magnetostrictive TransducersShock and Vibration, 2015
- Design of Compensation Coils for EMI Suppression in Magnetostrictive Linear Position SensorsSensors, 2012
- Theory, Instrumentation and Applications of Magnetoelastic Resonance Sensors: A ReviewSensors, 2011
- A Two-Port Nonlinear Model for Magnetoelastic Energy-Harvesting DevicesIEEE Transactions on Industrial Electronics, 2010
- Giant magnetostrictive actuators for active vibration controlSmart Materials and Structures, 2004
- Magnetostrictive actuation in microsystemsSensors and Actuators A: Physical, 2000
- Actuators, transducers and motors based on giant magnetostrictive materialsJournal of Alloys and Compounds, 1997
- Development and Analysis of a Self-Sensing Magnetostrictive Actuator DesignJournal of Intelligent Material Systems and Structures, 1995
- The Application of Smart Structures to the Vibration Suppression ProblemJournal of Intelligent Material Systems and Structures, 1992
- A Self-Sensing Piezoelectric Actuator for Collocated ControlJournal of Intelligent Material Systems and Structures, 1992