Development of Splice Connections for Precast Concrete Structures
Authors:
- 1 June 2014
- journal article
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 980, 132-136
Abstract
This paper presents the test results of proposed grouted sleeve connections under increasing tensile load. The objective of this research was to investigate splice connections that could provide tensile strength similar to the full tensile strength of the connected rebars. The parameters varied were splice types, splice length and rebar embedment length. The performance of the splice connection was evaluated based on the load-displacement, ultimate load, displacements and failure modes. The results show that the strength of splice connection depends on the bond strength between sleeve-to-grout and grout-to-rebar; the tensile strength of spliced steel bars and also the tensile strength of sleeve. It is observed that when the grout compressive strength is more than 60N/mm2and bar embedded length is at least 10 bar diameter, the splice connection in BS series is able to provide full tensile strength of the connected rebars.Keywords
This publication has 4 references indexed in Scilit:
- Behaviour of grouted pipe splice under incremental tensile loadConstruction and Building Materials, 2012
- Grout-Filled Pipe Splices for Precast Concrete ConstructionPCI Journal, 1995
- Mechanics of Bond and Slip of Deformed Bars in ConcreteACI Journal Proceedings, 1967
- Influence of Normal Pressure on Bond StrengthACI Journal Proceedings, 1965