Pulse glucometry: a new approach for noninvasive blood glucose measurement using instantaneous differential near-infrared spectrophotometry
Authors:
Open Access
- 1 January 2006
- journal article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 11 (5) , 054028-054028-9
Abstract
We describe a new optical method for noninvasive blood glucose (BGL) measurement. Optical methods are confounded by basal optical properties of tissues, especially water and other biochemical species, and by the very small glucose signal. We address these problems by using fast spectrophotometric analysis in a finger, deriving 100 transmittance spectra per second, to resolve optical spectra of blood volume pulsations throughout the cardiac cycle. Difference spectra are calculated from the pulsatile signals, thereby eliminating the effects of bone, other tissues, and nonpulsatile blood. A partial least squares (PLS) model is used with the measured spectral data to predict BGL levels. Using glucose tolerance tests in 27 healthy volunteers, periodic optical measurements were made simultaneously with collection of blood samples for in vitro glucose analysis. Altogether, 603 paired data sets were obtained in all subjects and two-thirds of the data or of the subjects randomly selected were used for the PLS calibration model and the rest for the prediction. Bland-Altman and error-grid analyses of the predicted and measured BGL levels indicated clinically acceptable accuracy. We conclude that the new method, named pulse glucometry, has adequate performance for safe, noninvasive estimation of BGL.
Keywords
This publication has 32 references indexed in Scilit:
- A Review of Continuous Glucose Monitoring TechnologyDiabetes Technology & Therapeutics, 2005
- A glucose-sensing contact lens: from bench top to patientCurrent Opinion in Biotechnology, 2005
- Non-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New MillenniumDiabetes Technology & Therapeutics, 2004
- Constrained optimization of Drude’s equations eliminates effects of confounding molecules for the polarimetric measurement of glucoseJournal of Biomedical Optics, 2004
- Transdermal monitoring of glucose and other analytes using ultrasoundNature Medicine, 2000
- Noninvasive Blood Glucose MonitoringDiabetes Care, 1997
- Reverse Iontophoresis: Noninvasive Glucose Monitoring in Vivo in HumansPharmaceutical Research, 1995
- Measurement of glucose in diabetic subjects using noninvasive transdermal extractionNature Medicine, 1995
- Design and Optimization of a Selective Subcutaneously Implantable Glucose Electrode Based on "Wired" Glucose OxidaseAnalytical Chemistry, 1995
- Noninvasive optical polarimetric glucose sensing using a true phase measurement techniqueIEEE Transactions on Biomedical Engineering, 1992